4. TROUBLE SHOOTING
- 47 -
Check C402,C404,C405
Check whether Ant SW
Set as RX mode
Refer to Table 4.2.2
Yes
Check SW501 Pin ANT,RF
with RF Cable connected.
Open
Yes
Changing SW401
Check SW501 Pin ANT,RF
with No RF Cable Connected
Short
Yes
Changing SW401
For these 2 test case,
No Call connection is needed
No
No
Changing the Board.
Ant SW & Mobile SW is OK
See next Page to check
Rx I/Q Signal
No
For this RF Level test case,
RX Stand alone Mode is needed
refer to chapter 10
Check Ant_SW1,
PA_EN, PA_BAND
CHECKING FLOW
Table 4.2.2
MODE
ANT_SW1
PA_EN
PA_BAND
GSM850 RX
H
L
L
PCS1900 RX
H
L
H
GSM850 TX
H
H
L
PCS1900 TX
H
H
H