10
EN
How to Install the Unit
1
Measure the space for installation to assure a
good fit. The air conditioner must be installed
firmly into place to prevent vibration and noise.
2
Avoid exposure to direct sunlight.
3
Remove all obstacles from the rear of the
unit. There must be at least 50 cm (20 in.)
of cleared space around the rear of the unit.
Obstacles restricting the airflow may reduce
the cooling efficiency of the unit.
4
The unit should be installed with a slight tilt
towards the outside to allow condensed water
to drain. (About 10~15 mm or 1/4 bubble with
Level)
Fence
Awning
Heat
radiation
Cooled air
10~15 mm
Over 50 cm
Foam
70-150 cm
Level
1/4 Bubble
CAUTION
•
The external grille must be exposed outside for
air discharge.
Drainage (Optional)
The base-pan may overflow due to high humidity.
To drain the excess water, remove the drain cap
from the base pan of the unit and secure the Drain
pipe.
1
Remove the rubber cap from the hole under
the base-pan.
2
Press the drain pipe into the hole by hanging
and pushing.
2
1
3
Connect the drain hose to the outlet located
on the bottom of the drain pipe. (You can
purchase the drain hose or tubing locally to
satisfy your particular needs. Drain hose is not
supplied.)
CAUTION
•
Take care when inserting the drain pipe. Push
away from the sharp edge to avoid slipping and
injuring yourself.