2). Installation of indoor & Outdoor
.
Indoor unit
Install the air conditioner in the location that satisfies the fol-
lowing conditions
.
• The place shall easily bear a load e
xceeding four times the
indoor unit’s w
eight.
• The place shall be ab
le to inspect the unit as the figure.
• The place where the unit shall be le
veled.
• The place shall easily connect with the outdoor unit.
• The place where the unit is not aff
ected by an electr
ical
noise.
• The place where air circulation in the room will be good .
• There should not be an
y heat source or steam near the
unit
Confirm the positional relationship betw
een the unit and
suspension bolts.
• Installation the ceiling opening to clean the filter or service
under the product.
A).Selection of the best location of Indoor
Inspection hole
(600 x 600)
Control box
H=20 or more
• Suitable dimension "H" is necessar
y to get a slooe
to drain as aiv
en in the fiaure
Side view
(unit: mm)
600
600
A(Min)
B(Min)
Ceiling
Service Space
A
B
Capacity(Btu/h)
A
B
18/24k
600
1100
(Length: mm)
Low static Duct type
Minimum height f
or motor replacement.
Less than 20cm
Hole size should be
more than the size of IDU
.
Insufficient space. Difficult f
or servicing
20cm to 100cm
2
Sufficient space in the ceiling for ser
vicing.
More than 100cm
1
Remarks
Distance between
False ceiling & Actual ceiling
Number of
Inspection hole
[Inspection Hole Standard]
Содержание JBNQ18GB2A2
Страница 8: ...Cooling Mode 8 ...
Страница 9: ...Auto Operation Mode 9 ...
Страница 10: ...Dehumidification Mode 10 ...
Страница 12: ...Temperature Setting Room Temperature Checking 12 ...
Страница 13: ...Timer 13 ...
Страница 17: ...Self diagnosis Function 17 ...
Страница 20: ...Wide LCD Wired Remote Controller Optional 20 ...
Страница 21: ......
Страница 22: ...27 Installer Setting Setting Address of Central Control ...
Страница 24: ...Installer Setting How to enter installer setting mode 25 ...
Страница 32: ...MEZ66178925 JB Q18GB2A2 R 410A Gas charge model ...