48
Hydro Kit
Summary
• You can set the product user functions.
• Some functions may not be displayed/operated in some product types.
Test
Description
Test Run
Checking whenever Amount of refrigerant is normal
3 Minutes Delay
Factory use only
Remote sensor active
Connection information about remote air sensor
Temp. sensor selection
Selection for setting temperature as air temperature or leaving water temperature
Dry Contact Mode
Setting dry contact auto start option.
Central Control Address
When Central Controller is installed, address assigning is set by this function.
Override Master/Slave
Override master/slave selection function is to prevent the unit’s different mode
operation. If the unit is set as the slave, it blocks a change of opposite operating
mode(cooling/heating).
Pump test run
Checking whether water circulation is normal.
Air cooling set temp.
Adjusting range of 'Setting Air Temperature' in cooling mode
Water cooling set temp.
Adjusting range of 'Setting Leaving Water Temperature' in cooling mode
Air heating set temp.
Adjusting range of 'Setting Air Temperature' in heating mode
Water heating set temp.
Adjusting range of 'Setting Heating Flow Temperature' in heating mode
DHW set temp.
Adjusting range of 'Setting DHW tank Heating Flow Temperature' in domestic hot
water tank heating mode
Cooling / Heating only mode
Setting the Operation mode lock
Water supply off temp. during cooling
Determine leaving water temperature when the unit is turned off. This funtion is
used for preventing condensation on the floor in cooling mode
Outdoor temp. for auto mode
Setting outdoor Min/Max temperature for auto mode
Indoor air temp. for auto mode
Setting indoor Min/Max temperature for auto mode
LWT for auto mode
Setting heating flow Min/Max temperature for auto mode
Tank disinfection setting 1
Setting start/maintain time for pasteurisation
Tank disinfection setting 2
Setting pasteurisation temperature
Tank setting1
Setting start temperature for operation
Tank setting2
Setting maintain temperature for operation
DHW time setting
Determine follow time duration : operation time of domestic hot water tank heating,
stop time of domestic hot water tank heating, and delay time of DHW tank heater
operating
Night time power setting
Setting to distinguish power-on time type of model using night power
TH on/off Variable, heating air
Setting Thermal on/off Air Temperature gap in heating mode
TH on/off Variable, heating water
Setting Thermal on/off Water Temperature gap in heating mode
TH on/off Variable, cooling air
Setting the step value to adjust air temperature gap in cooling mode
TH on/off Variable, cooling water
Setting the step value to adjust water temperature gap in cooling mode
TH on/off Variable, DHW
Setting the step value to adjust DHW temperature gap in heating mode
Heating temp. setting
Setting the temperature of entering or leaving water in heating mode
Cooling temp. setting
Setting the temperature of entering or leaving water in cooling mode
Pump setting in heating
Setting options of water pump operation / delay time in heating mode
Pump setting in cooling
Setting options of water pump operation / delay time in cooling mode
Forced operation
Setting of Forced product operation
System Set-Up