ELECTRICAL CONNECTIONS
(cont.)
IF COOKTOP IS USED IN A NEW BRANCH CIRCUIT INSTALLATION (1996 NEC), MOBILE
HOME, RECREATIONAL VEHICLE, OR WHERE LOCAL CODES DO NOT PERMIT
GROUNDING TO THE NEUTRAL (WHITE) WIRE
Observe all governing codes and local
ordinances.
Disconnect the power supply.
At the circuit breaker box, fuse box or
junction box, connect appliance and power
supply cable wires as shown.
1
2
If connecting to a 4-wire power supply cable
electrical system, the appliance frame
connected ground wire MUST NOT be
connected to the neutral wire of the 4-wire
electrical system.
4-WIRE GROUNDED JUNCTION BOX
I N S TA L L AT I O N I N S T RU C T I O N S
COOKTOP INSTALLATION
Visually inspect the cooktop for damage.
Make sure all cooktop screws are tight
(see below for locations).
1
Screws
Carefully lower the cooktop into the counter-
top cutout, making sure not to trap any wires.
NOTE:
Do not use caulking compound. The
cooktop must be removable, should service
be required.
2
Do not remove the nylon spacers on the
edges of the cooktop. These spacers center
the cooktop in the space provided. The
cooktop must be centered to allow proper
venting and to prevent excess heat buildup
that may result in heat damage or fire.
Nylon spacers
Cable from power supply
Ground
wire
Black
wires
Green wire (ground)
Cable from cooktop
UL-listed conduit
connector
Junction box
Red
wires
White wire
(no connection)
WARNING
WARNING
Содержание HN7413AG
Страница 31: ...31 ENGLISH NOTES ...