Automatic ice maker operation needs water pressure of 147~834 kPa (1.5~8.5 kgf/cm
2
)
(The pressure is correct when an instant paper cup (180 cc) is in 3 sec.).
•
If water pressure does not reach the rating 147 kPa (1.5 kgf/cm
2
) or below, it is
necessary to purchase a separate pressure pump for normal automatic icing and cool
water feed.
•
Keep the total length of the feed water pipe tube within 6.5 m and be careful that the
tube does not bend. If the tube is 6.5 m or longer it may cause water feed problems
owing to the drain water pressure.
•
Install the feed water pipe tube at a place free from heat.
•
Connect to drinking water supply only.
Door Height adjustment
Level the door by inserting flat( - type) driver into the groove of the left height
adjusting screw and rotate it clockwise ( ).
Level the door by inserting flat( - type) driver into the groove of the left height
adjusting screw and rotate it clockwise ( ).
If the freezer
compartment
door is lower than
the refrigerator
compartment
door
If the freezer
compartment
door is higher than
the refrigerator
compartment
door
Height
Height
Left height
adjustment screw
Right height
adjustment screw
①
①
11
Installation
Model:
GSL32*****, GSP32*****, GWL27****, GWP27****
The refrigerator doors will close smoothly by adjusting the front side using the
height adjustment screw. If the doors do not close correctly, performance may be
affected.
1. Wipe off all dust accumulated during shipping and clean your appliance
thoroughly.
2. Install accessories such as the ice cube box, cover evaporating tray, etc., in their
proper places. They are packed together to prevent possible damage during
shipping.
3. Connect the power supply cord (or plug) to the outlet. Don’t double up with
other appliances on the same outlet.
After levelling