4.3 Charging trouble
Check Points
-Connection of TA (check TA voltage 4.8V)
-Charging Current Path component voltage drop
-Battery voltage
1 Charging method : CC-CV
2 Charger detect voltage : 4.0 V
3 Charging time : 2h 00m
4 Charging current : 645 mA
5 CV voltage : 4.2 V
6 Cutoff current : 105 mA
7 Full charge indication current (icon stop current) : 105 mA
8 Recharge voltage : 4.16 V
4.2V~3.74V 3.73V~3.65V 3.65V~3.59V 3.59V~3.35V
TP1
TP2
K3.
3
60
2
R
BQ25040
U201
5
6
7
4
8
3
9
2
10
1
11
PGND
IN
BAT
ISET
_PG
VSS1
CHG
LDO
VSS2
EN_SET
IFULL
1u
C210
1u
C212
VIO_2V62
VIO_2V62
50
2
R
I
N
D
C224
1u
VBAT
VIO_2V62
V_BUS
K0
01
32
2
R
02
8
70
2
R
K0
01
42
2
R
_CHG_EOC
_PPR
_CHG_EN
RPWRON_EN
Single Charging IC for uUSB
)
%
1
(
(645mA)
)
%
1
(
(105mA)
TP2
TP1