1-10. Temperature compensation and over-cool/weak-cool compensation circuit
1. Temperature compensation at freezing room, cold storage room
1) GR-L207ERA, GR-L247ERA
2) GR-B207ERA, GR-B247ERA
u
Temperature compensation table by adjustment value (difference value against current temperature)
Ex) If changing compensation resistance at a cold storage room (RCR1) from 10 k
Ω
(current resistance) to 18 k
Ω
(modified resistance), temperature at the cold storage will increase by +1°C.
EXPLATION FOR MICOM CIRCUIT
- 43 -
Freezing room
Cold storage room
Resistance value
Temperature
Resistance value
Temperature
Remarks
(RCF1)
compensation (RCR1)
compensation
180 k
Ω
+5 °C
180 k
Ω
+2.5 °C
Warmly
56 k
Ω
+4 °C
56 k
Ω
+2.0 °C
compensate
33 k
Ω
+3 °C
33 k
Ω
+1.5 °C
18 k
Ω
+2 °C
18 k
Ω
+1.0 °C
12 k
Ω
+1 °C
12 k
Ω
+0.5 °C
10 k
Ω
0 °C
10 k
Ω
0 °C
Reference temperature
8.2 k
Ω
-1 °C
8.2 k
Ω
-0.5 °C
5.6 k
Ω
-2 °C
5.6 k
Ω
-1.0 °C
3.3 k
Ω
-3 °C
3.3 k
Ω
-1.5 °C
2 k
Ω
-4 °C
2 k
Ω
-2.0 °C
Coolly
470
Ω
-5 °C
470
Ω
-2.5 °C
compensate
Содержание GR-L208NN
Страница 42: ...2 GR B207ERA GR B247ERA EXPLATION FOR MICOM CIRCUIT 42 ...
Страница 48: ...2 GR B207ERA GR B247ERA EXPLATION FOR MICOM CIRCUIT 48 ...
Страница 49: ...3 2 Parts list 1 GR L207ERA GR L247ERA EXPLATION FOR MICOM CIRCUIT 49 ...
Страница 50: ...EXPLATION FOR MICOM CIRCUIT 50 ...
Страница 51: ...2 GR B207ERA GR B247ERA EXPLATION FOR MICOM CIRCUIT 51 ...
Страница 52: ...EXPLATION FOR MICOM CIRCUIT 52 ...
Страница 54: ...EXPLATION FOR MICOM CIRCUIT 54 ...
Страница 55: ...2 GR B207ERA GR B247ERA EXPLATION FOR MICOM CIRCUIT 55 ...
Страница 56: ...EXPLATION FOR MICOM CIRCUIT 56 ...
Страница 63: ...CIRCUIT 63 ...
Страница 64: ...CIRCUIT 64 ...
Страница 118: ...P No 3828JD8467B DEC 2002 Printed in Korea ...