5-3. Sensor resistance characteristics table
u
The tolerance of the sensor resistance is °±3%.
u
Measure the resistance value of the sensor after leaving it for more than 3 minutes (delay is required due to sensing
speed.)
u
Always use a digital tester. Analog testers have a higher margin of error.
u
For left and right sensor of lid and drawer, measure both sensor ends of the connector after separating the connectors of
CON 2, 3, 4, 5, CON101 of PWB (PCB) assembly and main part. For the outside sensor, measure end of 2 and 5 of
CON101.
MICOM function and circuit description
- 25 -
Measuring temperature (°C)
-20°C
77 K
Ω
-15°C
60 K
Ω
-10°C
47.3 K
Ω
-5°C
38.4 K
Ω
0°C
30 K
Ω
+5°C
24.1 K
Ω
+10°C
19.5 K
Ω
+15°C
15.9 K
Ω
+20°C
13 K
Ω
+25°C
11 K
Ω
+30°C
8.9 K
Ω
+40°C
6.2 K
Ω
+50°C
4.3 K
Ω
CON5
CON4
CON3
CON2
Lid left compartment, lid right compartment, drawer left
compartment, drawer right compartment, outside sensor