5-2-9. Storing temperature compensation and over-cool/under-cool cut compensation circuit
(1) Storing temperature compensation
u
This is the circuit to input the temperature compensation level required for adjusting storage temperature at the left or
right compartment of the lid or drawer.
u
Temperature compensation table by adjustment of resistance value (difference against current temperature)
Ex) If you change the resistance of compensation at the lid left compartment (RCL) from 10K
Ω
(current resistance) to
18K
Ω
(adjusted resistance), the storage temperature in the lid left compartment will be increased by 1°C .
MICOM function and circuit description
- 20 -
470
Ω
2 K
Ω
3.3 K
Ω
5.6 K
Ω
8.2 K
Ω
10 K
Ω
12 K
Ω
18 K
Ω
33 K
Ω
56 K
Ω
180 K
Ω
470K
Ω
No change
0.5°C UP
1°C UP
1.5°C UP
2°C UP
2.5°C UP
3°C UP
3.5°C UP
4°C UP
4.5°C UP
5°C UP
2 K
Ω
0.5°C DOWN No change
0.5°C UP
1°C UP
1.5°C UP
2°C UP
2.5°C UP
3°C UP
3.5°C UP
4°C UP
4.5°C UP
3.3 K
Ω
1°C DOWN 0.5°C DOWN No change
0.5°C UP
1°C UP
1.5°C UP
2°C UP
2.5°C UP
3°C UP
3.5°C UP
4°C UP
5.6 K
Ω
1.5°C DOWN 1°C DOWN 0.5°C DOWN No change 0.5°C UP
1°C UP
1.5°C UP
2°C UP
2.5°C UP
3°C UP
3.5°C UP
8.2 K
Ω
2°C DOWN 1.5°C DOWN 1°C DOWN 0.5°C DOWN No change
0.5°C UP
1°C UP
1.5°C UP
2°C UP
2.5°C UP
3°C UP
10 K
Ω
2.5°C DOWN 2°C DOWN 1.5°C DOWN 1°C DOWN 0.5°C DOWN No change
0.5°C UP
1°C UP
1.5°C UP
2°C UP
2.5°C UP
12 K
Ω
3°C DOWN 2.5°C DOWN 2°C DOWN 1.5°C DOWN 1°C DOWN 0.5°C DOWN No change
0.5°C UP
1°C UP
1.5°C UP
2°C UP
18 K
Ω
3.5°C DOWN 3°C DOWN 2.5°C DOWN 2°C DOWN 1.5°C DOWN 1°C DOWN 0.5°C DOWN No change
0.5°C UP
1°C UP
1.5°C UP
33 K
Ω
4°C DOWN 3.5°C DOWN 3°C DOWN 2.5°C DOWN 2°C DOWN 1.5°C DOWN 1°C DOWN 0.5°C DOWN No change
0.5°C UP
1°C UP
56 K
Ω
4.5°C DOWN 4°C DOWN 3.5°C DOWN 3°C DOWN 2.5°C DOWN 2°C DOWN 1.5°C DOWN 1°C DOWN 0.5°C DOWN No change
0.5°C UP
180 K
Ω
5°C DOWN 4.5°C DOWN 4°C DOWN 3.5°C DOWN 3°C DOWN 2.5°C DOWN 2°C DOWN 1.5°C DOWN 1°C DOWN 0.5°C DOWN No change
Lid left
compartment
(RCUL)
Lid right
compartment
(RCUR)
Drawer left
compartment
(RCBL)
Drawer right
compartment
(RCBR)
Modified
resistance
Classification
Current
resistance
Lid left compartment
Lid right compartment Drawer left compartment Drawer right compartment
Temperature
Remarks
(RCUL)
(RCUR)
(RCBL)
(RCBR)
compensation value
180 K
Ω
+2.5 ˚C
Warmer
56 K
Ω
+2.0 ˚C
33 K
Ω
+1.5 ˚C
18 K
Ω
+1.0 ˚C
12 K
Ω
+0.5 ˚C
10 K
Ω
0 ˚C
Standard temperature
8.2 K
Ω
-0.5 ˚C
5.6 K
Ω
-1.0 ˚C
3.3 K
Ω
-1.5 ˚C
2 K
Ω
-2.0 ˚C
Cooler
470
Ω
-2.5 ˚C
Содержание GR-K243UG
Страница 8: ...Chapter 4 Circuit diagram Circuit diagram 8 ...
Страница 28: ... 28 MICOM function and circuit description ...
Страница 30: ... 30 MICOM function and circuit description ...
Страница 33: ...MICOM function and circuit description 33 PWB PCB ASSEMBLY DISPLAY 6871JB1395 6871JB1463 LED Module ...
Страница 35: ... 35 MICOM function and circuit description ...
Страница 52: ...P No MFL31842101 MAR 2008 Printed in Korea ...