5-3. Sensor resistance characteristics table
u
The tolerance of the sensor resistance is ±3%.
u
Measure the resistance value of the sensor after leaving it for more than 3 minutes (delay is required due to sensing
speed.)
u
Always use a digital tester. Analog testers have a higher margin of error.
u
For left and right sensor, measure both sensor ends of the connector after separating the connectors of CON2 and 3 of
PWB (PCB) assembly and main part. For the outside sensor, measure end of 2 and 5 of CON5.
MICOM function and circuit description
- 24 -
Measuring temperature (°C)
Left sensor, right sensor, outside sensor
-20°C
77 K
Ω
-15°C
60 K
Ω
-10°C
47.3 K
Ω
-5°C
38.4 K
Ω
0°C
30 K
Ω
+5°C
24.1 K
Ω
+10°C
19.5 K
Ω
+15°C
15.9 K
Ω
`
+20°C
13 K
Ω
+25°C
11 K
Ω
+30°C
8.9 K
Ω
+40°C
6.2 K
Ω
+50°C
4.3 K
Ω