![LG GR-B652Y*B Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/lg/gr-b652y-b/gr-b652y-b_service-manual_1902647025.webp)
- 25 -
6-2 PTC AND OLP
Normal operation of
Compressor is
impossible or poor.
Separate the PTC from
Compressor and
measure the resistance
between No. 5 and 6
(only RSIR Type) or No.
4 and 5 of PTC with a
Tester or Wheat stone
bridge. (Figure 22)
Separate the OLP from
Compressor and check
resistance value
between two terminals
of OLP with a Tester.
(Figure 23)
Observation value at
220V/50Hz : 47
30%
220 - 240V/50Hz : 47
30%
110 -115V/60Hz : 6.8
30%
220V/60Hz : 47
30%
127V/60Hz : 22
30%
The resistance value is 0
or several hundreds
or infinity.
Check another electric
components.
Replace OLP.
Check another
electric components.
Replace PTC.
NO
YES
Figure 22
Figure 23