3-4 DEF' CONTROL ASSY
3-6 CONTROL BOX-R
3-5 LAMP
3-5-1 Freezer room lamp
Def control ASM consists of Defrost Sensor and FUSE-M.
Defrost Sensor functions to defrost automatically and it is
attached to the Evaporator and the metal side of the case
senses Temp.
Fuse-M is a kind of safety device for preventing overheating
of the Heater when defrosting.
At the temperature of 77°C, it stops the emission of TEMP
from the Defrost Heater.
1. Pull out the shroud-F after removing the Grille Fan.
(Figure 13)
2. Separate the connectors connected with the Def Control
ASM and replace the Def Control ASM after cutting the
Tie Wrap. (Figure 14)
1. Unplug the power cord from the outlet.
2. Remove the room lamp lid by loosening 1screw and
take down while pulling it forward with both hands as
shown in figure.
3. Remove the lamp by turning it counterclockwise.
3-5-2 Refrigerator room lamp
1. Unplug the power cord from the outlet.
2. Remove refrigerator shelves.
3. Remove the room lamp lid by pulling it forward.
4. Make sure the bulbs are cool to the touch. Remove the
lamp by turning it counterclockwise.
1. First, remove all shelves in the refrigerator.
2. Loosen 1 screws fixing the Control Box-R to
The Inner Case.
3. Remove the Control Box-R by pulling it downward.
SHROUD-F
FREEZER ROOM LAMP
REFRIGERATOR ROOM LAMP
DEF CONTROL ASM
MULTI FLOW
DUCT
Figure 13
Figure 16
Figure 17
Figure 14
Figure 18
Содержание GR-B652Y*B
Страница 47: ... 47 7 5 2 REPLACEMENT PARTS LIST ...
Страница 48: ... 48 ...
Страница 49: ... 49 7 5 3 PWB ASS Y DISPLAY AND PARTS LIST ...
Страница 50: ... 50 7 5 4 PWB ASS Y DISPLAY I MICOM AND PARTS LIST ...
Страница 51: ... 51 7 5 5 V LED DISPLAY PART LIST ...
Страница 52: ... 52 7 6 PWB DIAGRAM ...
Страница 53: ... 53 ...
Страница 57: ...P No MFL62196001 NOV 2006 Printed in Korea ...