5-8
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE
OUTER CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE
HIGH VOLTAGE TRANSFORMER. (SEE PAGE 2-1)
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER
OF WATER IN CONTAINER) IN THE OVEN.
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
TRANSFORMER
(Wire leads removed)
MAGNETRON
(Wire leads removed)
1. Measure the resistance.
(Ohm-meter scale: Rx1 and Rx100)
¥ Primary winding
¥ Secondary winding
¥ Filament winding
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
¥ Primary winding to ground
¥ Filament winding to ground
1. Measure the resistance.
(Ohm-meter scale: Rx1)
¥ Filament terminal
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
¥ Filament to chassis
Approx.: 0.2 ~ 0.4 ohm
Approx.: 60 ~ 90 ohm
Less than: 1 ohm
Normal: Infinite
Normal: Infinite
Normal: Less than 1 ohm
Normal: Infinite
FILAMENT
WINDING
PRIMARY
TERMINAL
COMPONENT TEST PROCEDURE
Содержание GoldStar MS-113YE
Страница 27: ...6 2 13552A 13213A 13352A 13581A 13720D 13806D 14970A 14026A 15006A 13536A DOOR PARTS ...
Страница 28: ...6 3 24781M 26638A 23572A 268711 WTP018 CONTROLLER PARTS ...
Страница 29: ...6 4 33052M 340511 36549S WTP013 33390G WTT010 WSZ185 33112U 35889A OVEN CAVITY PARTS ...
Страница 30: ...6 5 43501A WSZ085 466002 466003 466001 43500A LATCH BOARD PARTS ...
Страница 32: ...6 7 63303L 56170D 63303R WSZ002 WTT021 WTT028 647781 BASE PLATE PARTS ...
Страница 33: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Страница 34: ...8 2 PRINTED CIRCUIT BOARD ...