7-1- 8 ERROR DIAGNOSTIC MODE
1. The error diagnostic mode allows the SVC when a fault that may affect the performance of the product occurs while
operating the product.
2. Even if the function control button is pushed when an error occurs, the function will not be performed. However, the
recognition tone (beep~) sounds.
3. When the error is cleared while the error code is displayed due to a fault, the appliance returns to the normal condition
(Reset).
4. The error code is displayed by the refrigerator temp indication LED on the display of the refrigerator while the remaining
LEDs are off.
- 21 -
u
G
N
-M492Y*Y
G
N
-
M
492Y*
Q
G
N
-B492Y*
Q
NO
Error
Error Code
Cause
State of Operation with Error
Display
Comp
Cooling fan
Defrosting heater
1
2
3
4
Faulty refrigerator
(R) sensor
Faulty defrosting
sensor
Faulty Room
temperature sensor
(in the main PCB)
Defrosting failure
r
d
when super cool and
refrigerator key pressed
together display will be all off
H
Cut or short-circuited wire of
refrigerator sensor
Cut or short-circuited wire of
defrosting sensor
Cut or short-circuited wire of
intake air temperature sensor
Cut or disconnected wire of
defrosting heater or temperature
fuse(indicated at least 4 hours
later after the error occurs)
15 min ON/
15 min OFF
Normal
Condition
Normal
Condition
Normal
Condition
Low
RPM
Low
RPM
Low
RPM
Low
RPM
No defrosting
Normal
Condition
Normal
Condition
Normal
Condition
Содержание GN-B492Y*C
Страница 35: ...7 5 2 REPLACEMENT PARTS LIST 35 ...
Страница 36: ... 36 ...
Страница 37: ...7 5 3 PWB ASS Y DISPLAY AND PARTS LIST 37 ...
Страница 38: ... 38 7 5 4 PWB ASS Y DISPLAY I MICOM AND PARTS LIST ...
Страница 39: ... 39 7 5 5 V LED DISPLAY PART LIST ...
Страница 40: ...7 6 PWB DIAGRAM 40 ...
Страница 41: ... 41 ...
Страница 48: ... 48 265K 267C 267J 267K 267D 267B 267H 267F 267G 267E 265J 267A 255A 265L 264M u GN M492Y Y ...