- 6 -
LGE Internal Use Only
Copyright © 2010 LG Electronics. Inc. All right reserved.
Only for training and service purposes
3. TECHNICAL BRIEF
3.4.3 Charging control
A programmable charging block in PM7540 is used for battery charging. It is possible to set limits for the
charging current. The external supply typically connects directly to pin (VCHG). The voltage on this pin
(VCHG) is monitored by detection circuitry to ascertain whether a valid external supply is applied or not.
For additional accuracy or to capture variations over time, this voltage is routed internally to the
housekeeping ADC via the analog multiplexer. PM7540 circuits monitor voltages at VCHARGER and
ICHARGE pins to determine which supply should be used and when to switch between the two supplies.
These pins are connected to the Source (or emitter) and Drain (or collector) contacts of the pass transistor
respectively.
3. Technical Brief
U8210 Charging Control
block
PM7540
Input Power
Management
NUS5530
PM7540 only include charging controller.
So it is necessary external charging path TR.
This is NUS5530.
This part also include battery side power path.
NUS5530
Содержание GD88O
Страница 1: ...Service Manual Model GD880 Internal Use Only Service Manual GD880 Date March 2010 Issue 1 0 ...
Страница 183: ... 184 LGE Internal Use Only Copyright 2010 LG Electronics Inc All right reserved Only for training and service purposes ...
Страница 199: ... 200 LGE Internal Use Only Copyright 2010 LG Electronics Inc All right reserved Only for training and service purposes ...
Страница 217: ... 218 LGE Internal Use Only Copyright 2010 LG Electronics Inc All right reserved Only for training and service purposes ...