Содержание / GD1329QES

Страница 1: ...CGS GD1329CES GD1329CGD GD1329CED GD1329CGW GD1329CEW GD1329CGS2 GD1329CES2 GD1329CGD2 GD1329CED2 GD1329CGW2 GD1329CEW2 GD1329QGS GD1329QES GD1329QGD GD1329QED GD1329QGW GD1329QEW GD1329QGS2 GD1329QES2 GD1329QGD2 GD1329QED2 GD1329QGW2 GD1329QEW2 GD1329LGS GD1329LES GD1329LGD GD1329LED GD1329LGW GD1329LEW GD1329LGS2 GD1329LES2 GD1329LGD2 GD1329LED2 GD1329LGW2 GD1329LEW2 ...

Страница 2: ...n energy saving system ARTISTIC DESIGN Modern front panel look and big clear glass door make your dryer look stylish EASY OF USE An entire selection of user friendly functions makes operating the dryer easy ULTRA CAPACITY The larger drum enables better tumbling and less tangling and wrinkling of the laundry PRODUCT FEATURES ...

Страница 3: ...se a load to catch fire Do not dry articles that have been previously cleaned in washed in soaked in or spotted with gasoline dry cleaning solvents or other flammable or explosive substances as they give off vapors that could ignite or explode Do not reach into the dryer if the drum or any other part is moving Do not repair or replace any part of the dryer or attempt any servicing unless specifica...

Страница 4: ... your building 3 Clear the room building or area of all occupants 4 Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions carefully 5 If you cannot reach your gas supplier call the fire department CALIFORNIA SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT This act requires the governor of California to publish a list of substances known to the state to cau...

Страница 5: ...ng Properly ground dryer to conform with all governing codes and ordinances Follow details in the installation instructions Electric shock can result if the dryer is not properly grounded Before use the dryer must be properly installed as described in this manual Electric shock can result if the dryer is not properly grounded Install and store the dryer where it will not be exposed to temperatures...

Страница 6: ...nstallation Ductwork is not provided with the dryer and you should obtain the necessary ductwork locally The end cap should have hinged dampers to prevent backdraft when the dryer is not in use Failure to follow these instructions can result in fire or death The exhaust duct must be 4 in 10 cm in diameter with no obstructions The exhaust duct should be kept as short as possible Make sure to clean ...

Страница 7: ...cked by a qualified electrician to make sure the outlet is properly grounded Failure to follow these instructions can create an electric shock hazard and or a fire hazard The dryer should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate This provides the best performance and also prevents overloading house wiring circuits which co...

Страница 8: ... type or coin type setup 22 3 3 Top off apply or not setup 23 4 How to enter the special price day setup 24 4 1 How to change sunday 25 5 Special price beginning time setup 26 6 Special price ending time setup 27 7 Regular priced dryer cycle time 28 8 Special priced dryer cycle time 29 9 Value of coin 1 30 10 Value of coin 2 Set up for top off price and e suds coin pulse 31 11 Penny increment pric...

Страница 9: ...d information Single dryer size 686mm W x 764mm D x 983mm H 27in W x 30in D x 38 7in H Stack dryer size 686mm W x 764mm D x 1954 H 27in W x 30in D x 76 9in H Capacity IEC 7 1 cu ft 22 5 lb Weight 131 Ibs 59 4 kg Specifications are subject to change by manufacturer Specifications subject to change by manufacturer NOTE ...

Страница 10: ...CGW2 GD1329CEW2 STACK LOWER GD1329CGD GD1329CED GD1329CGD2 GD1329CED2 1 2 4 3 4 1 2 4 3 1 2 4 3 1 2 4 OPL TYPE SIDE BY SIDE GD1329LGS GD1329LES GD1329LGS2 GD1329LES2 STACK UPPER GD1329LGW GD1329LEW GD1329LGW2 GD1329LEW2 STACK LOWER GD1329LGD GD1329LED GD1329LGD2 GD1329LED2 1 2 4 3 1 DISPLAY LED 2 CYCLE BUTTON 3 START BUTTON 4 STATUS LED ...

Страница 11: ...QES2 3 1 2 4 3 1 2 4 3 1 2 4 3 1 2 4 COIN TYPE STACK UPPER GD1329QGW GD1329QEW GD1329QGW2 GD1329QEW2 3 1 2 4 3 1 2 4 3 1 2 4 3 1 2 4 COIN TYPE STACK UPPER GD1329QGD GD1329QED GD1329QGD2 GD1329QED2 3 1 2 4 3 1 2 4 3 1 2 4 3 1 DISPLAY LED 2 CYCLE BUTTON 3 START BUTTON 4 STATUS LED ...

Страница 12: ...t Med Temp Use for drying sturdy fabrics such as work casual clothes Medium heat Low Temp Use for drying synthetic fabrics washable knit fabrics and no iron finishes Low heat No Heat Use for items that require heat free drying such as plastics or rubber 3 START BUTTON The Start LED flashes when the full vend price has been satisfied then the cycle has been chosen or the machine is paused The Start...

Страница 13: ... or the chosen course button has been pressed The card should have enough balance to satisfy increasing time The operating time can be increased to 15 minutes 25 default by adding more coins When the COOL DOWN has been working if time is added it goes back to the DRYING Time can be added up 99 minutes 5 Change cycle You cannot change the cycle while the machine is running But if the door is opened...

Страница 14: ...Low Temp button at the same time 2 Push the Med Temp button 3 times 3 Push the Srart button 4 Display will show How to use button You can change Dryer vend price cycle time and Cycle parameters etc Press button Description High Temp Move to upper level Med Temp Move to the mode in the same level Low Temp Move to the modes in the same level No Heat Start Enter the selected mode If you turn on the p...

Страница 15: ...ng set up mode 2 Press High Temp button to move the upper level 3 Press Med Temp or Low Temp button if you want to be at the same level 4 Press Start button to enter the details of Set up Diagnostic Tests mode is to set price value time value and vend type etc consists of line test reset free cycle and kill cycle Is to collect the usage data STRUCTURE OF PROGRAMMING MODE Do not use It is only used...

Страница 16: ... Type 1 Push the High Temp and Low Temp button at the same time 2 Push the Med Temp button 3 times 3 Push the Srart button 4 Display will show is to set price value time value and vend type etc consists of line test reset free cycle and kill cycle Is to collect the usage data STRUCTURE OF PROGRAMMING MODE Do not use It is only used in inspecting the machine NOTE ...

Страница 17: ...e is not available in dryer NOTE Entering set up mode You will see LqC1 Button Display Press the High Temp button Press the Med Temp or the Low Temp button until appears in the display Press the Start button Press the Start button Display previous regular price Press Med Temp or Low Temp button to set regular price The vend price can be set from 0 to 9 95 in 5 increments Press the Start button The...

Страница 18: ...utton until appears in the display Press the Start button Press the Med Temp or the Low Temp button until appears in the display Press the Start button Display previous special price Press Med Temp or Low Temp button to set special price The vend price can be set from 0 to 9 95 in 5 increments Press the Start button The machine sets up the regular price then advances to the next process automatica...

Страница 19: ...s the Med Temp or the Low Temp button until appears in the display Press the Start button Press the Med Temp or the Low Temp button until appears in the display Special price days apply or not Disabled Add super wash apply or not Select vend type This function is not available Pre wash apply or not Top off apply or not only for dryer Disable Enable ...

Страница 20: ...s the Med Temp or the Low Temp button until appears in the display Press the Start button Display Press the Start button Press Med Temp or Low Temp button and then select or Disable Enable One or the other will display Press the Start button The machine sets up the special price then advances to the next process automatically 1 Continue to set up the next price 2 Stop the change of setup value and...

Страница 21: ...d Temp or the Low Temp button until appears in the display Press the Start button Press the Med Temp or the Low Temp button until appears in the display Press the Start button Display Press the Med Temp or the Low Temp button until appears in the display Press the Start button Press Med Temp or Low Temp button and then select or Coin type Card type One or the other will display Press the Start but...

Страница 22: ...play Press the Med Temp or the Low Temp button until appears in the display Press the Start button Press Med Temp or Low Temp button and then select or Disable Enable One or the other will display Press the Start button The machine sets up the Vend type then advances to the next process automatically 1 Continue to set up the next price 2 Stop the change of setup value and go back to ready mode Coi...

Страница 23: ...tton Display Press the High Temp button Press the Med Temp or the Low Temp button until appears in the display Press the Start button Press the Med Temp or the Low Temp button until appears in the display Press the Start button Display Structure of Sunday Monday Tuesday Wednesday Thursday Friday Saturday ...

Страница 24: ...Temp button until appears in the display Press the Start button Display Press the Start button Press Med Temp or Low Temp button and then select or Disable Enable One or the other will display Press the Start button The machine sets up the special price day Sunday then advances to the next process automatically 1 Continue to set up the next price 2 Stop the change of setup value and go back to rea...

Страница 25: ...the display Press the Start button Display previous special price beginning time Press Med Temp or Low Temp button to select time between 0 and 23 Press the Start button The machine sets up the special price beginning time then advances to the next process automatically 1 Continue to set up the next price 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switc...

Страница 26: ...ous special price ending time Press Med Temp or Low Temp button to select time between 0 and 23 Press the Start button The machine sets up the special price ending time then advances to the next process automatically 1 Continue to set up the next price 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control...

Страница 27: ...isplay Press the Start button Display previous regular priced dryer cycle time Press Med Temp or Low Temp button to select time between 10 and 99 Press the Start button The machine sets up the regular priced dryer cycle time then advances to the next process automatically 1 Continue to set up the next price 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle swi...

Страница 28: ...w Temp button to select time between 10 and 99 Press the Start button The machine sets up the special priced dryer cycle time then advances to the next process automatically 1 Continue to set up the next price 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control panel open 2 Turn on off toggle switch CCC...

Страница 29: ...he Start button Display previous coin 1 value Press Med Temp or Low Temp button to select value of coin 1 The value can be set fronm 0 to 9 95 in 5 increments Press the Start button The machine sets up the value of coin 1 then advances to the next process automatically 1 Continue to set up the next price 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch...

Страница 30: ...e of coin 2 The value can be set fronm 0 to 9 95 in 5 increments Press the Start button The machine sets up the value of coin 2 then advances to the next process automatically 1 Continue to set up the next price 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control panel open 2 Turn on off toggle switch C...

Страница 31: ...ay Press the Start button Display previous penny increment pricing offset Press Med Temp or Low Temp button to select value of PIPo 0 4 Press the Start button The machine sets up the PIPo then advances to the next process automatically 1 Continue to set up the next price 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card S...

Страница 32: ...s in the display Press the Start button Display previous top off time Press Med Temp or Low Temp button to select time between 1 and 30 Press the Start button The machine sets up the top off time then advances to the next process automatically 1 Continue to set up the next price 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the servic...

Страница 33: ... Press the Start button Display previous value Press Med Temp or Low Temp button to select High or Low or Off Press the Start button The machine sets up the beep volume then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control ...

Страница 34: ...until appears in the display Press the Start button Display previous value Press Med Temp or Low Temp button to select time between 1 180 or Disable Press the Start button The machine sets up the time to keep the coin then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card...

Страница 35: ...ring programming mode Insert service card card type Turn on off toggle switch Coin type 2 High Temp Press the High Temp button Then appears in the display 3 Start Enter the diagnostic test mode OPL 1 Entering programming mode Push and hold the High Temp and Low Temp at the same time After that push Med Temp button for 3 times Push Start but ton 2 High Temp Press the High Temp button Then appears i...

Страница 36: ...s Motor Valve Current temperature 5 70 Displays the temperature inside the drum in Celsius 5 time ELECTRIC TYPE Heater runs Motor Heater 1 Heater 2 5400W GAS TYPE GAS valve runs Motor Valve Current temperature 5 70 Displays the temperature inside the drum in Celsius 6 time LED KEY CHECK Press High Temp button Press Med Temp button Press Low Temp button Press No Heat button Version and code of mach...

Страница 37: ...e display Press the Start button then factory reset is done is displayed 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control panel open 2 Turn on off toggle switch OPL type Push High Temp Low Temp and the 3 Dryer default value Drying time 45 Minute Top off time 15 Minu...

Страница 38: ...the month then advances to the next process automatically Press Med Temp or Low Temp button to select day between 01 and 31 Press the Start button The machine sets up the day then advances to the next process automatically Press Med Temp or Low Temp button to select hour between 00 and 23 Press the Start button The machine sets up the hour then advances to the next process automatically Press Med ...

Страница 39: ...ears in the display Press the Start button Press the Med Temp button until appears in the display Press the Start button Display will show Select the course you desire In case of dryer card type it has to insert the cash card after removing the service card Then press the cycle course and the start button It is only applicable to the dryer s card type specially and there is no subtraction in card ...

Страница 40: ...til appears in the display Press the Start button Press the Med Temp button until appears in the display Press the Start button Display with beeping Go back to ready mode Insert cycle kill card Descriptions Display Display the current time and Display with beeping Go back to ready mode OPL type Dryer machine will end the cycle by opening the door NOTE ...

Страница 41: ...enter 5 dELC Dryer Moisture Sense dELC is not available in dryer It can t enter 6 ItrC Interval Regular Cycles Number of Regular cycles 0 65535 7 ItCC Interval Regular Cold Cycles ItCC is not available in dryer It can t enter 8 ItAC Interval Regular Warm Cycles ItAC is not available in dryer It can t enter 9 ItHC Interval Regular Hot Cycles ItHC is not available in dryer It can t enter 10 ItSC Int...

Страница 42: ...e Door Openings 0 255 29 ItAC Interval Authorized Coin Vault Openings Number of Authorized Service Door Openings 0 255 30 tLdo Time of Last Service Door Opening tLdo is not available in dryer It can t enter 31 tLCo Time of Last Coin Vault Opening tLCo is not available in dryer It can t enter 32 tPdo Time of Previous Service Door Opening tPdo is not available in dryer It can t enter 33 tPCo Time of...

Страница 43: ...abrasive cleansers they can scratch or damage the surface Cleaning Around and Under the Dryer Vacuum lint and dust from around the dryer and underneath it regularly Vent ductwork should be checked for lint buildup and cleaned at least once per year If any noticeable reduction in airflow or drying performance occurs immediately check ductwork for obstructions and blockages Maintaining Ductwork Vent...

Страница 44: ...29QEW2 GD1329QGD2 GD1329QED2 GCW1069QD2 GD1329LGW2 GD1329LEW2 GD1329LGD2 GD1329LED2 GCW1069LD2 2 STACKING KIT STACKING KIT is provided in the upper dryer STACKING KIT includes the stacking bracket 1 security bracket 3 bolt 1 screw 9 SLIDING KIT includes the slide bracket 2 sliding pad 4 screw 18 1 Stacking bracket 2 bolt 3 Screw 4 security bracket The machine can be stacked only on the model desig...

Страница 45: ... of the lower washer in the same position Push the upper dryer matching the slide stacking bracket to make upper and lower front parallel Install the stacking bracket at the rear of the stacked dryer and washer Assemble the six 6 screw to fix the lower machine and upper dryer Security bracket installation Only coin model Install two security bracket on the panel frame and top plate in the lower wa...

Страница 46: ...currence or problem Dryer error code POWER FAIL RECOVERY In case of power failure the machine stops running but the time display remains on showing the time just before power failure Press the Start button after the power is restored then the machine will restart DEFAULT DRYER SETTINGS Default Settings Default Cycle Time Minutes 45 Minutes Cool Down Time Cycle 2 Minutes High Temperature 154 4 F 68...

Страница 47: ...47 ...

Страница 48: ......