3-2. WATER LEVEL CONTROL
●
This model incorporates a pressure sensor which can sense the water level in the tub.
●
The water supply is stopped when the water level reaches the preset level; then the selected cycle begins.
●
Spinning does not proceed until the water in the tub drains to a certain level.
3-3. DOOR CONTROL
●
The door can be opened by pulling the door handle whenever washer is not in operation.
●
When the cycle is completed, the DOOR LOCKED light will turn off.
●
If a power failure has occurred while in operation, the door will unlock after 2 minutes.
●
Clicking sounds can be heard when the door is locked/unlocked.
3-4. THE DOOR CAN NOT BE OPENED
●
While program is operating.
●
While Door Lock lights turn on.
●
While the drum is rotating.
3-5. DOOR LOCKED LAMP LIGHTS
●
When the frequency of water level is lower than 22.9 kHz.
(It can be canceled when the frequency is more than 23.8 kHz.)
●
When the temperature inside the tub is higher than 45° C (104° F) and water level is not 25.5 kHz.
(It can be canceled when the water level is 25.5 kHz or the temperature inside the tub is lower than
40° C (113° F). )