PTC
- 10 -
6
5
YES
NO
Poor starting or no
operating of the
Compressor.
First, separate the PTC from
the Compressor and check the
voltage between NO 5 and 6
in the PTC with a multitester
or Wheatstone Bridge.
Separate the OLP from
the Compressor and
check resistance value
between two terminals of
OLP with Tester.
The value is in the
range of 15-28 for
the 22
Ω
PTC.
Check another
electric components.
Replace OLP.
The value is 0.
The value is
∞
.
Normal
Check another
electric
components.
Replace the
PTC.
Replace the
PTC.
Abnormal
Abnormal