- 64 -
6. Over cooling in Refrigerator compartment
No
1
Checking flow
Check the sensor resistance.
2
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
3
Open the refrigerator door and
Check the air flow.
The sensor is determined by
the temperature.
For example, 30 indicates 32°F.
Result & SVC Action
Temperature
23°F / -5°C
32°F / 0°C
41°F / 5°C
50°F / 10°C
59°F / 15°C
Result
38
30
24
19.5
16
Status
Windy
No windy
SVC Actio
n
Go to the 4
Check the damper
(Go to the 5)
4
Input Test 2 Mode and
Check the air flow.
(Push the button 1 time)
Status
Windy
No windy
SVC Action
Go to the 5
It’s normal
<CON5>
Содержание GB7138**XZ Series
Страница 30: ... 30 CIRCUIT DIAGRAM ...
Страница 35: ... 35 Figure 24 LOKRING TOOL Figure 23 LOKRING ...
Страница 44: ... 44 PCB Picture 1 Main PCB P No MFG EBR652501 Picture CON5 CON1 CON2 CON201 CON3 CON6 CON8 ...
Страница 45: ... 45 2 Display PCB P No EBR64736301 EBR65008001 EBR65255701 Picture EBR65256001 ...
Страница 74: ...P No MFL64999802 JAN 2011 Printed in Poland ...