5. Defrost Heater Error (dH F)
Fuse-M
Def
Heater
Def
Sensor
0
34~42
0
Go to the 3
Change Fuse-M
Go to the 3
Change Fuse-M
Go to the 3
Replace product
Part
Result
SVC Action
No
1
2
Checking flow
Check the Door gasket.
Check the Defrost control part.
3
Input Test 2 Mode.
(Push the button 2 times)
4
Check the Brown to Blue.
Result & SVC Action
Fuse M
Def Heater
Def Sensor
5
Release the test mode.
Push the button 1 times. (Normal)
<CON3>
Result
220 ~ 240 V
0 V
SVC Action
Go to the 5
Replace Main PCB
6
Check the Brown to Blue.
Result
0 V
220 ~ 240 V
SVC Action
Explain to customer
Replace Main PCB
<CON3>