2. NO RASTER : [B] Process
Check LED status
On Display Unit.
Fail
Repeat A PROCESS.
Fail
Check Panel Link Cable
or Module.
Change Panel Link Cable
or Module.
Check Inverter
Connector or inverter.
Change Inverter Connector
or Inverter.
Change IC100
Check Output
of R305
Check the LVDS Output
of IC100
Check Input source Cable
and Jack.
Change Module.
Change R305
Pass
Pass
Pass
Pass
Pass
Fail
Fail
Fail
Fail