background image

Owner's Manual 

11

ENGLISH

ON

OFF

CANCEL

AUTO CLEAN

SET

1

3

5

4

9

10

12

14

7

2

8

13

11

15

6

Cooling Operation

Auto Operation

Healthy Dehumidification Operation

• Cooling Model(     ), Heat Pump Model(     )

Flip-up door
(opened)

Signal transmitter

16

Operation Mode

Operating Instructions

The controls will look like the following.

Wireless Remote Controller

1. START/STOP BUTTON

Used to turn off/on the unit.

2. OPERATION MODE SELECTION BUTTON

Used to select the operation mode.

3. ROOM TEMPERATURE SETTING BUTTONS

Used to select the room temperature.

4. INDOOR FAN SPEED SELECTOR BUTTON

Used to select fan speed in four steps
low, medium, high and CHAOS.

5. JET COOL BUTTON

Used to start or stop the speed cooling.
(It operates fan in super high speed in cooling mode)

6. CHAOS SWING BUTTON

Used to stop or start louver movement and set the
desired up/down airflow direction.

7. ON/OFF TIMER BUTTONS

Used to set the time of starting and stopping
operation. 

8. TIME SETTING BUTTONS

Used to adjust the time. 

9. TIMER SET/CANCEL BUTTON

Used to set and to cancel the timer operation.

10. SLEEP MODE AUTO BUTTON

Used to set sleep mode auto operation. 

11. AIR CIRCULATION BUTTON

Used to circulate the room air without cooling

12. ROOM TEMPERATURE CHECKING BUTTON

Used to check the room temperature.

13. RESET BUTTON

Used prior to resetting time.

14. 2nd F BUTTON

Used prior to using modes printed in blue at the
bottom of buttons.

15. PLASMA BUTTON(OPTIONAL)

Used to start or stop the plasma-purilication
function.
Optional : Plasma function (button #15) may not be

worked for specific model

16. AUTO CLEAN BUTTON

Used to set auto clean mode.

To use the functions printed in blue at the bottom of the buttons press 2

nd 

F button first and then the required  function

button. Pressing the 2

nd

F button activates the blue printed function of the respective button. To cancel the  function

press the  2nd F button again else it will automatically cancel if remains idle after 10 seconds.

NOTE

Содержание F122CS N012

Страница 1: ...this owner s manual for future reference after reading it thoroughly Dear Owner Thank you for installing LG air conditioner Your best choice guarantees you a great performance and service to make your life comfortable pleasant P No 3828A20894R ENGLISH ESPAÑOL MODELS F242CX UO F362CX UO F363CX UO F483CX UO F122CS N012 F182CS N018 F242CS N024 F242HX UO F362HX UO F363HX UO F483HX UO F122HS N012 F182H...

Страница 2: ...ldren or invalids without supervision Young children should be supervised to ensure that they do not play with the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts A Safety Precautions 3 B Electrical Safety 8 Temporary Use of an Adapter 8 Temporary Use of an Extension Cord 8 Symbols used in t...

Страница 3: ...re to follow the instruction Installation Do not use a defective or underrated circuit breaker Use this appliance on a dedicated circuit There is risk of fire or electric shock For electrical work contact the dealer seller a qualified electrician or an Authorized Service Center Do not disassemble or repair the product There is risk of fire or electric shock Always ground the product There is risk ...

Страница 4: ...duct on a defective installation stand It may cause injury accident or damage to the product Be sure the installation area does not deteriorate with age If the base collapses the air conditioner could fall with it causing property damage product failure and personal injury Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open Moisture...

Страница 5: ...nge sounds or small or smoke comes from product Turn the breaker off or disconnect the power supply cable There is risk of electric shock or fire When the product is soaked flooded or submerged contact an Authorized Service Center There is risk of fire or electric shock When the product is not be used for a long time disconnect the power supply plug or turn off the breaker There is risk of product...

Страница 6: ...e property It may cause a problem for your neighbors Use two or more people to lift and transport the product Avoid personal injury Do not install the product where it will be exposed to sea wind salt spray directly It may cause corrosion on the product Corrosion particularly on the condenser and evaporator fins could cause product malfunction or inefficient operation 90 Do not expose the skin dir...

Страница 7: ...ct malfunction or damage Do not insert hands or other objects through the air inlet or outlet while the product is operated There are sharp and moving parts that could cause personal injury Do not drink the water drained from the product It is not sanitary and could cause serious health issues Use a firm stool or ladder when cleaning or maintaining the product Be careful and avoid personal injury ...

Страница 8: ... Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection To disconnect the power cord from the adapter use one hand on each to avoid damaging the ground terminal Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage Never use the appliance with a broken adapter We strongly discourage the us...

Страница 9: ...ical blades Indoor Units Air intake vents Air outlet vents Connecting wires Refrigerant pipes Drain hose Base plate On Off Lights up during the system operation error code and auto restart setting Sleep mode Lights up during sleep mode auto operation non Inverter Model Timer Lights up during timer operation non Inverter Model Lights up during timer operation or sleep mode auto operation Inverter M...

Страница 10: ...e controller starts fading replace both of the batteries NOTE 1 Choose a suitable place where its safe easy to reach 2 Fix the holder to wall etc with the supplied screws firmly 3 Slide the remote controller inside the holder 1 Remote controller should never be exposed to direct sunlight 2 Signal transmitter receiver should always be clean for proper communication Use a soft cloth to clean them 3 ...

Страница 11: ...UTTONS Used to set the time of starting and stopping operation 8 TIME SETTING BUTTONS Used to adjust the time 9 TIMER SET CANCEL BUTTON Used to set and to cancel the timer operation 10 SLEEP MODE AUTO BUTTON Used to set sleep mode auto operation 11 AIR CIRCULATION BUTTON Used to circulate the room air without cooling 12 ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature 13 RESET B...

Страница 12: ...or cooling or heating operation set the desired indoor temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS For cooling the temperature can be set within 18 C 30 C and for heating the temperature range is 16 C 30 C Set the fan speed with the remote controller You can select the fan speed in four steps low medium high and CHAOS by pressing the INDOOR FAN SPEED SELECTOR BUTTON Each time the ...

Страница 13: ...emperature If you feel hot or cold press the temperature setting buttons respectively for more cooling or heating effect NOTE You cannot set the actual setting temperature and the indoor fan speed in this operation mode But you can use the Chaos swing in this operation If the system is not operating as desired switch manually to another mode To run the healthy dehumidification mode follow steps 1 ...

Страница 14: ...uxe model you can use jet heat function by pressing JET COOL BUTTON for heating operation Art Cool and Art Cool Wide models close the side discharges during jet cool heat operation for strong cooling and heating NOTE Forced operation Operation procedures when the remote control can t be used The operation will be started if the ON OFF button is pressed If you want to stop operation re press the bu...

Страница 15: ...rature as long as sleep mode is functioning NOTE 1 Time can be set only when you press the RESET BUTTON Having replacing the batteries you should press the RESET BUTTON to reset the time Press the Start Stop button 2 Press 2nd F button and check if icon is on 3 Press the TIME SETTING BUTTONS until the desired time is set 4 Press the TIME SET CANCEL BUTTON Check the indicator for A M and P M NOTE 1...

Страница 16: ...nd could damage the mechanism When the unit is shut off the up down airflow direction louver will close the air outlet vent of the system NOTE The up down airflow Vertical airflow can be adjusted by using the remote controller 1 Press the START STOP BUTTON to start the unit 2 Press CHAOS SWING BUTTON 3 The louvers will swing up down automatically 4 To stop the louver at a desired angle press again...

Страница 17: ...pe models where there is no AIR CIRCULATION BUTTON air circulation can be operated by pressing the PLASMA BUTTON NOTE This feature is enabled by factory default setting but you can disable it by pressing the ON OFF button for 6 seconds The unit will beep twice and the indicator lamp 2 will blink 4 times To enable it press the button again for 6 seconds The unit will beep twice and the indicator la...

Страница 18: ... for each model type Clean the filters with a vacuum cleaner or warm soapy water If dirt is not easily removed wash with a solution of detergent in luke warm water Dry well in shade after washing and reinstall the filters back in place Removal of Filters Gasoline Powder Maintenance and Service Deodorizer filter Deodorizing Filter 1 After removing the air filters pull slightly forward to remove the...

Страница 19: ...niform temperature in the room Make sure that the doors and windows are shut thight Avoid opening doors and windows as much as possible to keep the cool air in the room Clean the air filter regularly Blockages in the air filter reduce the airflow and lower cooling and dehumidifying effects Clean at least once every two weeks Ventilate the room occasionally Since windows are kept closed it is a goo...

Страница 20: ...re blocking the front of the air conditioner Clean the filter at least every 2 weeks See the Maintenance and Service section When the air conditioner is first turned on you need to allow time for the room to cool down Check for open furnace floor registers and cold air returns Make sure they are correct Check and remove such source or turn it off while using the air conditioner What To Do Possible...

Страница 21: ...Impreso en Corea LG ELECTRONICS MEXICO S A DE C V Sor Juana Ines de la Cruz No 555 San Lorenzo Tlalnepantla Estado de Mexico C P 54033 TEL 55 5321 1994 01800 3471919 ...

Отзывы: