PF (Power Failure or no power)
Is the Power Plug connected
firmly to the power outlet?
And is the supply voltage
220~240V AC?
Is
Red LED ON
while power supplied ?
Is Multi-plug socket used ?
NO
NO
NO
YES
YES
YES
NO
Is the connectors connected
Correctly to the Display
PCB?
Is the
Connector
connected correctly to
the
Main PCB
and the
Noise Filter
?
Is the
Harness
alright ?
Reconnect
Power Plug
firmly.
Check the fuse or
reset the circuit breaker.
Don’t use
Multi-plug
socket.
Use
Single Plug
socket for
washing machine.
YES
YES
Reconnect or repair the
Connector
.
Or replace the
Harness
.
Check connectors otherwise.
Replace
Display PCB
.
Check and replace
Main PCB
.
8. TROUBLESHOOTING WITHOUT ERROR CODES
Noise Filter
PCB
Main PCB
42
Содержание F V5 RP Series
Страница 6: ...3 PARTS IDENTIFCATION 6 ...
Страница 7: ...3 PARTS IDENTIFCATION 5 9 6 ...
Страница 9: ...1 2 3 1 2 3 9 ...
Страница 51: ...9 Par t i nspect i on 51 ...
Страница 52: ...52 ...
Страница 53: ...53 ...
Страница 54: ...54 ...
Страница 55: ...I II I I I II I II II I I I I I I I 9 4 I I I I I I I ...
Страница 69: ...THE EXPLODED VIEW OF DRYER M110 M120 M100 M120 M216 M215 M100 M240 M111 M110 M101 ...
Страница 70: ...P No MFL69882928 ...