7-5. TROUBLESHOOTING WITH ERROR
Symptom
Check Point
1.INLET VALVE
ERROR
1.Check Electric Wiring.
2.Check Inlet valve’s Resistance.
3.Check Inlet valve clogged.
4.Voltage of the inlet valve’s connector.
- LQC mode : Valve running with 13.6V ± 10%
- In normal cycle : Valve running with 7V±10%
Need to check 2s later from valve start to running
Pre wash
Main wash
Filter Cleaan
Steam&Condensate
24
Содержание F V5 RP Series
Страница 6: ...3 PARTS IDENTIFCATION 6 ...
Страница 7: ...3 PARTS IDENTIFCATION 5 9 6 ...
Страница 9: ...1 2 3 1 2 3 9 ...
Страница 51: ...9 Par t i nspect i on 51 ...
Страница 52: ...52 ...
Страница 53: ...53 ...
Страница 54: ...54 ...
Страница 55: ...I II I I I II I II II I I I I I I I 9 4 I I I I I I I ...
Страница 69: ...THE EXPLODED VIEW OF DRYER M110 M120 M100 M120 M216 M215 M100 M240 M111 M110 M101 ...
Страница 70: ...P No MFL69882928 ...