RECOMMENDATIONS AND SUGGESTIONS

 

INSTALLATION 

 The manufacturer will not be held liable for any damages resulting from 

incorrect or improper installation. 

 The minimum safety distance between the cooker top and the extractor 

hood is 650 mm. 

 Check that the mains voltage corresponds to that indicated on the rating 

plate fixed to the inside of the hood. 

 For Class I appliances, check that the domestic power supply guarantees 

adequate earthing. 

  Connect the extractor to the exhaust flue through a pipe of minimum diame-

ter 120 mm. The route of the flue must be as short as possible. 

 Do not connect the extractor hood to exhaust ducts carrying combustion 

fumes (boilers, fireplaces, etc.). 

 If the extractor is used in conjunction with non-electrical appliances (e.g. 

gas burning appliances), a sufficient degree of aeration must be guarante-
ed in the room in order to prevent the backflow of exhaust gas. The kitchen 
must have an opening communicating directly with the open air in order to 
guarantee the entry of clean air. 

 Installation of the extractor hood over a solid-fuel burner(coal, wood,etc.) 

which could constitute a potential fire hazard (e.g. due to flying sparks) is 
only permitted if the burner is equipped with an enclosed, non-removable 
cover and all country-specific regulations are observed. This restriction do-
se not apply to gas cookers and gas hobs. 

  Regulations concerning the discharge of air have to be fulfilled. 

USE 

  The extractor hood has been designed exclusively for household use to eliminate kitchen smells. 
  Never use the hood for purposes other than for which it has been designed. 
  Never leave high naked flames under the hood when it is in operation. 
  Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the si-

des. 

  Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames. 
  The hood should not be used by children or persons not instructed in its correct use. 
  Do not use the appliance if it is damaged in any way. 
  Never operate the extractor hood without a grease filter. 
  Do not flambe food directly under the extractor hood. 

MAINTENANCE 

  Switch off or unplug the appliance from the mains supply before carrying out any maintenance work. 
  Clean and/or replace the Filters after the specified time period. 
  Clean the hood using a damp cloth and a neutral liquid detergent. 
  Defective bulbs should be replaced immediately to prevent the remaining bulbs from overloading. 
  There is a fire risk if cleaning is not carried out in accordance with the instructions. 

 

650 mm min.

Содержание DT6101SAU

Страница 1: ...Instruction Manual Part NO 383EW5N001T MFL30049915 Model Numbers DT6101SAU DT6101SSA ...

Страница 2: ...EN 2 2 Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 5 USE 7 MAINTENANCE 8 ...

Страница 3: ...f the burner is equipped with an enclosed non removable cover and all country specific regulations are observed This restriction do se not apply to gas cookers and gas hobs Regulations concerning the discharge of air have to be fulfilled USE The extractor hood has been designed exclusively for household use to eliminate kitchen smells Never use the hood for purposes other than for which it has bee...

Страница 4: ...ight Blower Filters 8 1 Directional Air Outlet grille 9 1 Flange ø 150 mm 10a 1 Reducer Flange ø 150 120 mm 10b 1 Damper 20 1 Closing element Ref Q ty Installation Components 12a 4 Screws 3 5 x 16 12e 2 Screws 2 9 x 12 7 12f 5 Screws 2 9 x 9 5 Q ty Documentation 1 Instruction Manual 9 1 12a 20 12f 10a 12e 8 10b ...

Страница 5: ...nected the relative fas tening elements Close the sliding suction panel again Insert the Hood until the snap on side sup ports click into place fig 4 Open the sliding suction panel Lock in position by tightening the screws Vf from underneath the Hood fig 4 If necessary adjust the whole filter holder unit and proceed as follows Loosen the four adjustment screws Vr and close the sliding panel again ...

Страница 6: ...rcoal filters ø 120 10b 9 10a ø 150 10b 9 RECIRCULATION VERSION AIR OUTLET Cut a hole ø 155 mm in the wall unit over the hood Insert the flange 9 on the hood body outlet Connect the hood body outlet to the top part of the wall unit using a rigid or flexible pipe ø 150 mm to be selected by the installer Fix the pipe in position using sufficient pipe clamps not supplied Fix the directional grille 8 ...

Страница 7: ...Switches the lighting system on and off M Motor Switches the extractor motor on and off 1 Low speed used for a continuous and silent air change in the presence of light cooking vapour 2 Medium speed suitable for most operating conditions thanks to an op timum relation between hood performance and noise 3 Maximum speed suitable when the highest cooking vapour emission has to be eliminated for longe...

Страница 8: ...LTERS These filters are not washable and cannot be regenerated and must be replaced approximately every four months or more frequently by particularly heavy use Pull out the sliding suction panel Remove the grease filters Remove the saturated carbon filter by releasing the fixing hooks Replace the grease filters Close the sliding suction panel Light Replacement 20 W Halogen lamp Remove the metal t...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ...436003255_ver2 ...

Отзывы: