50
Steam Dryer™ Models DT22BSSG DT22VSSG DT21VS DT21VSE
Description
Steam Dryer
Electrical requirements
Gas : 120 V~ 60 hz 400 W
Elec : 120/240 V~ 60 hz 5550W
Gas requirements
NG: 4-10.5 inches WC
LP: 8–13 inches WC (Gas Models only)
Max. water pressure
21.8 ~ 116 psi (150 ~ 800 kPa)
Dimensions
27” (W) X 29 1/2” (D) X 40 7/16” (h), 50 1/4” (D with door open)
68.6 cm (W) X 75 cm (D) X 102.7 cm (h), 127.5 cm (D with door open)
Net weight
Gas dryer : 126.8 lbs (57.5 kg)
Electric dryer : 123.7 lbs (56.1 kg)
Drying capacity
- Normal cycle
207 L (22.5 lb/10.2 kg)
SPECIFICATIONS
Before Calling for Service (cont.)
Problem
Possible Causes
Solutions
There are no
creases left on
garment after
Steam Fresh™
• The function of this cycle is to
remove wrinkles from fabric.
• Use an iron to make creases.
Odors remain
in clothing after
Steam Fresh™
• Steam Fresh™ did not remove
odor completely.
• Fabrics containing strong odors should be washed in a
normal cycle.
Sensor de Flujo
(Flow Sense)
indicator
shows four
bars during the
drying cycle
or the display
shows “d80”
after drying.
• Ductwork is too long or has too
many turns/restrictions.
• Significant blockage of the
ductwork due to lint buildup or
debris.
• The appliance has detected a
restriction in the external dryer
venting.
• Install a shorter or straighter duct run. See the Installation
Instructions.
• Ductwork should be checked/cleaned soon.
Dryer can be used in this condition, but drying times may
be longer.
• If exhaust restrictions are sensed by the Sensor de Flujo
(Flow Sense) system, the indicator will remain on for two
hours after the end of the cycle. Opening the door or
pressing the ENCENDIDO/APAGADO (POWER) button will
turn off the display.
The display
shows
“d90”, “d95”
• The duct work is about 90%-95%
blocked.
(“d90” or “d95” error code
displayed 2 hours only)
• house exhaust system blocked.
• Do not use the dryer until the exhaust system has been
cleaned and/or repaired. Using the dryer with a severely
restricted exhaust is dangerous and could result in a fire
or other property damage.
• Check the outside dryer vent while the dryer is operating
to make sure there is strong airflow.
• If the exhaust system is extremely long, have it repaired or
rerouted.
• Keep the area around the dryer clean and free of clutter.
• Check vent hood for damage or lint clogging.
• Make sure the area around the vent hood is clear.
TROUBLESHOOTINg / SPECIFICATIONS