9-2 Installation Test (Exhaust check)
33
Once you have completed the installation of the dryer,
use this test to make sure the condition of the exhaust
system is adequate for proper operation of the dryer.
This test should be performed to alert you to any serious
problems in the exhaust system of your home.
•
Your dryer features FLOW SENSE
TM
, an innovative
sensing system that automatically detects blockages
and restrictions in dryer ductwork. Keeping ductwork
clean of lint buildup and free of restrictions allows
clothes to dry faster and reduces energy use.
To activate the Installation test:
1.
Remove the drying rack and literature, and then
close the door.
Do not load anything in the drum for this test, as it
may affect the accuracy of the results.
2.
Press and hold the SIGNAL ON/OFF and TEMP.
CONTROL buttons and then press the POWER
button.
This button sequence activates the
installation test. The code
will display if the
activation is successful.
3.
Press START/PAUSE button.
The dryer will start the test, which will last about
two minutes. The heat will be turned on and the
temperatures in the drum will be measured.
4.
Check the display for results.
During the test cycle, monitor the FLOW SENSE
TM
display on the control panel. If no bars are displayed,
when the cycle ends, the exhaust system is
adequate. If the exhaust system is severely restricted,
the display will show four bars.
Other problems may also be shown with error codes.
Refer to the next page for error code details and
solutions.
Four bars indicates that the exhaust system is severely
restricted. Have the system checked immediately, as
performance will be poor.
5.
End of cycle.
At the end of the test cycle,
will display.
The test cycle will end and the dryer will shut off
automatically after a short delay.
NOTE
The dryer should be cool before starting this test. If
the dryer was warmed up during installation, run the
AIR DRY cycle for a few minutes to reduce the interior
temperature.
NO BARS:
OK
FOUR BARS:
RESTRICTED
29
• Check the Error Code before you call for service
Error Code
P
ossible Causes
Solutions
tE1
or
tE2
• Temperature sensor failure
•
HS
• Humidity Sensor failure.
•
PS
or
PF
or
nP
• Electric dryer power cord is not
connected correctly, or house power
supply is incorrect.
• House fuse is blown, circuit breaker has
tripped, or power outage has occurred.
• Check the power supply or the connection of
power cord to the terminal block. Refer to the
Connecting electric dryers
section of this
manual for complete instructions.
• Reset circuit breaker or replace fuse. Do not
increase the fuse capacity. If the problem is a
circuit overload, have it corrected by a quali-
The display
Do not use the dryer until the exhaust
system has been cleaned and/or repaired.
Using the dryer with a severely restricted exhaust
property damage.
Check the outside dryer vent while the dryer is
.
If ther exhaust system is extremely long, have it
repaired or rerouted.
Keep the area around the dryer clean and free
of clutter.
Check the vent hood for damage or lint clogging.
Make sure the area around the vent hood is clear.
FLOW SENSE
TM
indicator shows
four bars during
the drying cycle
or the display
drying.
many turns/restrictions.
ductwork due to lint buildup or
debris.
restriction in the external dryer
venting.
Install a shorter or straighter duct run. See the
Instructions.
Ductwork should be checked/cleaned soon.
Dryer can be used in this condition, but drying
times may be longer.
TM
If exhaust restrictions are sensed by the
FLOW SENSE system, the indicator will remain
on for two hours after the end of the cycle.
Opening the door or pressing the POWER button
n
o
i
t
i
d
n
o
c
t
c
u
d
e
h
t
k
c
e
h
C
•
If the FLOW SENSE
TM
LED is turned on, check the
exhaust system for restrictions and damage. Repair or
replace the exhaust system as needed.
Avoid long runs or runs with multiple elbows or
bends.
Excess or crushed
transition duct
Too many elbows or
exhaust too long
Check for blockages and lint buildup.
Make sure the ductwork is not crushed or restricted.
Crushed or
damaged
exhaust
Lint buildup
or blockage
Содержание DLEX8000
Страница 11: ...11 Connecting electric dryers ...
Страница 15: ...15 Connecting Electric Dryers cont USA only ...
Страница 21: ...21 7 WIRING DIAGRAM 23 7 WIRING DIAGRAM ...
Страница 52: ...52 13 EXPLODED VIEW 54 A211 A210 A120 A110 A130 F211 F215 13 EXPLODED VIEW ...
Страница 53: ...53 55 K503 K508 K501 A090 K507 K505 K502 A160 A170 K504 K506 A161 A172 A171 A350 ...
Страница 58: ...MAR 2017 PRINTED IN KOREA P No MFL62119939 ...