13
13. Outlet Thermostat
(Auto reset)
14. Outlet Thermostatt
(Manual reset)
Measure resistance of terminal
to terminal
Open at 203 41°F (95 5°C
Close at 159 41°F (70 5°C)
• Gas type
• Gas funnel
• Gas type
• Gas funnel
Measure resistance of terminal
to terminal
Open at 230 41°F
(110 5°C)
Manual reset
Resistance value
Continuity
<
1
Ω
•
Check Top Marking:
N95
•
Check Top Marking:
N100
Resistance value
Continuity
<
1
Ω
Component Test Procedure Check result