22
Once you have completed the installation of the dryer,
use this test to make sure the condition of the exhaust
system is adequate for proper operation of the dryer.
This test should be performed to alert you to any serious
problems in the exhaust system of your home.
FLOW SENSE
TM
, an innovative
sensing system that automatically detects blockages
clean of lint buildup and free of restrictions allows
clothes to dry faster and reduces energy use.
1.
door.
Do not load anything in the drum for this test, as it
may affect the accuracy of the results.
2.
This sequence activates the insallation
3.
The dryer will start the test, which will last about
two minutes. The heat will be turned on and the
temperatures in the drum will be measured.
4.
During the two minute test cycle, monitor the FLOW
SENSE
TM
display on the control panel. If the Flow
Sense indicator text lights up, the exhaust system
is restricted. If the indicator text remains dark, the
exhaust system is adequate.
Other problems may also be shown with error codes.
Refer to the next page for error code details and
solutions.
Have the system checked immediately, as performance
will be poor.
5.
At the end of the test cycle,
will display.
The test cycle will end and the dryer will shut off
automatically after a short delay.
NOTE
The dryer should be cool before starting this test. If
the dryer was warmed up during installation, run the
AIR DRY cycle for a few minutes to reduce the interior
temperature.
LIGHTED:
RESTRICTED
test. The code will display if the activation
is successful.
23
• Check the Error Code before you call for service
Error Code
P
ossible Causes
Solutions
tE1
or
tE2
• Temperature sensor failure
•
HS
• Humidity Sensor failure.
•
PS
or
PF
or
nP
• Electric dryer power cord is not
connected correctly, or house power
supply is incorrect.
• House fuse is blown, circuit breaker has
tripped, or power outage has occurred.
• Check the power supply or the connection of
power cord to the terminal block. Refer to the
Connecting electric dryers
section of this
manual for complete instructions.
• Reset circuit breaker or replace fuse. Do not
increase the fuse capacity. If the problem is a
circuit overload, have it corrected by a quali-
The display
Do not use the dryer until the exhaust
system has been cleaned and/or repaired.
Using the dryer with a severely restricted exhaust
property damage.
Check the outside dryer vent while the dryer is
.
If ther exhaust system is extremely long, have it
repaired or rerouted.
Keep the area around the dryer clean and free
of clutter.
Check the vent hood for damage or lint clogging.
Make sure the area around the vent hood is clear.
FLOW SENSE
TM
indicator shows
four bars during
the drying cycle
or the display
drying.
many turns/restrictions.
ductwork due to lint buildup or
debris.
restriction in the external dryer
venting.
Install a shorter or straighter duct run. See the
Instructions.
Ductwork should be checked/cleaned soon.
Dryer can be used in this condition, but drying
times may be longer.
TM
If exhaust restrictions are sensed by the
FLOW SENSE system, the indicator will remain
on for two hours after the end of the cycle.
Opening the door or pressing the POWER button
n
o
i
t
i
d
n
o
c
t
c
u
d
e
h
t
k
c
e
h
C
•
If the FLOW SENSE
TM
LED is turned on, check the
exhaust system for restrictions and damage. Repair or
replace the exhaust system as needed.
Avoid long runs or runs with multiple elbows or
bends.
Excess or crushed
transition duct
Too many elbows or
exhaust too long
Check for blockages and lint buildup.
Make sure the ductwork is not crushed or restricted.
Crushed or
damaged
exhaust
Lint buildup
or blockage
Содержание DLEX5000 series
Страница 2: ...2 ...
Страница 6: ...6 ...
Страница 8: ...8 ...
Страница 9: ...9 3 2 Connecting the gas supply ...
Страница 10: ...10 21 8 150 800 800 Connect Inlet Hose ...
Страница 13: ...13 ...
Страница 14: ...14 Ω Ω Electric type 15 Inlet valve Measure resistance of the Following terminal Left picture plate ...
Страница 15: ...15 Ω Ω Ω Ω When checking Component be sure to turn Power off then do voltage discharge sufficiently m ...
Страница 16: ...16 Heater Relay Black Heater Relay Blue AG Heater Relay White YL3 WH4 BL2 NA7 NA6 NA4 ...
Страница 17: ...17 Heater Relay Black Heater Relay Blue YL3 WH4 BL2 NA7 NA6 NA4 BL3 ...
Страница 19: ...19 ...
Страница 21: ...21 ...
Страница 25: ...25 120V AC Electrical Supply ...
Страница 26: ...26 t r c t c o m h t t ...
Страница 27: ...27 ...
Страница 28: ...28 Thermistor Test Measur e with Power Off ...
Страница 29: ...29 Ω Ω Ω Ω Ω Motor Test Drum does not rotate fan does not turn heater does not function page 12 l i page 15 i ...
Страница 30: ...30 Moistur e sensor Moisture Sensor Ω l l d t ...
Страница 31: ...31 Door Switch Test Ω Ω Ω Ω h half d p o ...
Страница 32: ...32 Heater Switch Test Electric Type Ω Ω Ω Ω Ω Ω ...
Страница 33: ...33 GAS V alve test Gas T ype GAS Valve Test Gas Type Ω dc ute dc dc s o l i ...
Страница 36: ...36 ...
Страница 50: ...50 A210 A227 A228 A212 A211 A214 A213 A217 A229 A218 A216 13 1 Plate Assembly ...
Страница 55: ...MAR 2017 PRINTED IN KOREA MFL69290403 ...