44
45
Test 7
Gas Valve test - Gas Type
When measuring power, be sure to wear insulated gloves to avoid electric shock.
While operating, heating will not work.
Drying time takes longer
With dryer power on
Power on & start (Normal cycle)
When measuring Valve 1 voltage,
is the valve at least 90 V DC?
Igniter operates?
(after 1 minute, igniter becomes reddish)
When measuring Valve 2 voltage, value is more
is the valve at least 90 V DC? (10 sec after igniter off)
When measuring terminal resistance on valve 1 and
valve 2, valves are more than1.5 ~ 2.5 k
Ω
?
(Measure after off )
If valve 1 and valve 2 read less than 10 V DC, are the
valves off?
• Harness check
• Controller change
•
Check thermostat
hi-limit safety
•
Check Igniter and
frame detect
•
Check gas
connection or
gas supply
• Change valve
• Change valve
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
Valve 1
NOTE:
When the gas valve operates after disassembling, ignition will be off several seconds.
It is normal because there is no circulation of air
Caution
Trouble Symptom
Measurement Condition
Valve 2
FOR LG TECHNICIAN
44
Содержание DLEX4270 /01 Series
Страница 25: ...25 Electric Dryer Table 1 Resistance for Thermistor Temperature ...
Страница 27: ...27 Gas Dryer ...
Страница 28: ...28 Gas Dryer Table 1 Resistance for Thermistor Temperature ...
Страница 64: ...64 MAR 2017 PRINTED IN KOREA MFL62119982 FOR LG TECHNICIAN ...