Component
Test Procedure
Check result
Remark
13. Outlet Thermostat
(Auto reset)
•
Check Top Marking:
N95
Measure resistance of terminal
to terminal
Open at 203 ± 41°F (95± 5°C)
Close at 158 ± 41°F (70± 5°C)
Resistance value
Continuity < 1
•
Gas type
•
Gas funnel
14. Outlet Thermostat
(Manual reset)
•
Check Top Marking:
N110
Measure resistance of terminal
to terminal
Open at 230 ± 41°F
(110 ± 5°C)
Manual reset
Resistance value
Continuity < 1
•
Gas type
•
Gas funnel
FOR LG TECHNICIAN