ENGLISH
Routing and Connecting Ductwork
Follow the guidelines below to maximize drying
performance and reduce lint buildup and
condensation in the ductwork.
NOTE:
Ductwork and fittings are NOT included
and must be purchased separately.
• Use 4-inch (10.2 cm) diameter rigid or semirigid
metal ductwork.
• The exhaust duct run should be as short as
possible.
• Use as few elbow joints as possible.
• The male end of each section of exhaust duct
must
point away from the dryer.
• Use duct tape on all duct joints.
• Insulate ductwork that runs through unheated
areas in order to reduce condensation and lint
buildup on duct surfaces.
IMPORTANT:
Failure to exhaust the dryer
correctly will void the dryer’s warranty.
VENTING THE DRYER
(cont.)
Correct Venting
Incorrect Venting
NOTE:
Deduct 6 ft. (1.8 m) for each additional elbow. It is not recommended to use more than four 90° elbows.
65 ft. (19.8 m)
55 ft. (16.8 m)
47 ft. (13.7 m)
36 ft. (11.0 m)
28 ft. (8.5 m)
55 ft. (16.8 m)
47 ft. (13.7 m)
41 ft. (12.5 m)
30 ft. (9.1 m)
22 ft. (6.7 m)
Ductwork
4"
(10.2 cm)
4"
(10.2 cm)
Recommended
2
1
/
2
"
(6.35 cm)
Use Only for Short
Run Installations
Wall Cap Type
0
1
2
3
4
0
1
2
3
4
Number of 90° Elbows
Maximum Length of 4-inch Diameter
Rigid Metal Duct
17
MFL67408111_EN_111004.indd 17
2011.10.4 10:40:25 AM