12
Use the instructions under option 2 or 3 if your
home has a 3-wire receptacle (NEMA type 10-30R).
Use option 2 if local codes and ordinances permit
the connection of a chassis ground to the neutral
connector. If this is not permitted, use option 3.
Review the following options to determine the appropriate electrical connection for your home:
Electric Dryer Only
If this type is available at your home. you will be
connecting to a fused disconnect or circuit breaker
box
Important : Grounding through the neutral conductor is
prohibited for (1) new branch-circuit installations, (2) mobile
homes, and (3) recreational vehicles, and (4) areas where local
codes prohibit grounding through the neutral conductor.
Prepare minimum 5ft(1.52m) of length in order for dryer to be
replaced.
First, peel 5 inch (12.7cm) of covering material from end.
Make a 5 inch of ground wire bared. After cutting 1
1
/2 inch
(3.8cm) from 3 other wires. peel insulation back 1inch
(2.5cm). Make ends of 3 wires a hook shape.
Then, put the hooked shape end of the wire under the screw of
the terminal block(hooked end facing rightward) and pinch the
hook together and screw tightly.
Use the instructions under option 1 if your home
homehas a 4-wire receptacle (NEMA type 14-30R).
If this type is available at your home. you will be
connecting to a fused disconnect or circuit breaker
box
1. Connect neutral wire(white) of power cord to center terminal block screw.
2. Connect red and black wire to the left and right terminal block screws.
3. Connect ground wire(green) of power cord to external ground
screw and move neutral ground wire of appliance and connect
it to center screw.
4. Make sure that the strain relief screw is tightened.
and be sure that all terminal block nuts are on tight and power
cord is in right position.
5"
(12.7 cm)
3
1
/
2
"
(8.6 cm)
1"
(2.5 cm)
(2.5 cm)
5"
(12.7 cm)
(12.7 cm)
1"
(2.5 cm)
3V
2
"
(8.9 cm)
3-wire direct
4-wire receptacle
(NEMA type14-30R)
3-wire receptacle
(NEMA type10-30R)
4-wire direct
5"
5"
(12.7 cm)
(12.7 cm)
3
1
/
2
"
(8.6 cm)
1"
(2.5 cm)
5"
(12.7 cm)
1"
(2.5 cm)
3V
2
"
(8.9 cm)
4-wire connection : Direct wire
5"
(12.7 cm)
3
1
/
2
"
(8.6 cm)
1"
1"
(2.5 cm)
(2.5 cm)
5"
(12.7 cm)
1"
(2.5 cm)
3V
2
"
(8.9 cm)
WARNING!
!
•
Disconnect power before servicing.
•
Replace all parts and panels before operating.
•
Be careful of the sharp edge on frame which makes you hurt.
•
Failure to follow these instructions can result in death or electrical shock.
• Connect the power supply wire to the terminal
block. Colored wire should be connected to
same color screw. Wire color indicated on
manual is connected to the same color screw in
block. Otherwise,a short or excessive current
flow may result.
Note