10
11
Important : Grounding through the neutral conductor
is prohibited for (1) new branch-circuit installations,
(2) mobile homes, and (3) recreational vehicles, and
(4) areas where local codes prohibit grounding through
the neutral conductor.
Prepare minimum 5 ft(1.52 m) of length in order for
dryer to be replaced.
First, peel 3
1
/
2
inch (8.9 cm) of covering material
from end and bare 1 inch from the ends.
1. Connect neutral wire(white) of power cord to
center terminal block screw.
2. Connect red and black wire to the left and right
terminal block screws.
3. Make sure that the strain relief screw is tightened
and be sure that all terminal block nuts are on
tight and power cord is in right position.
Then, put the hooked shape end of the wire under
the screw of the terminal block(hooked end facing
rightward) and pinch the hook together and screw
tightly.
1"
(2.5
cm
)
3V
2
"
(8.9 cm)
3-wire connection : Direct wire
1. Connect the neutral wire (white) of the power
cord to the center terminal block screw.
2. Connect the red and black wires to the left and
right terminal block screws.
3. Connect the ground wire (green) of the power
cord to the external ground screw. Remove the
neutral ground wire of appliance and connect it to
center screw.
4. Make sure that the strain relief screw is tightened
and that all terminal block nuts are tight and the
power cord is in the right position.
F
a
b
E
D
C
: 4-wire connection with
a power supply cord.
E
a
D
B
C
lf your local codes or ordinances do not allow the
use of a 3 wire connection, or you are installing
your dryer in a mobile home, you must use a
4-wire connection.
4-prong plug
4-prong plug
Neutral prong
Neutral prong
Содержание DLE3500 series
Страница 13: ...13 3 3 Connect Inlet Hose 21 8 150 800 800 ...
Страница 18: ...18 15 ...
Страница 19: ...19 16 Ω Ω Electric type 15 Inlet valve Measure resistance of the Following terminal Left picture plate ...
Страница 21: ...21 7 WIRING DIAGRAM 18 ELECTRIC DRYER GAS DRYER ...
Страница 22: ...22 Main PCB Picture Electric Gas 19 ...
Страница 24: ...24 21 ...
Страница 25: ...25 22 ...
Страница 27: ...27 Electric Dryer Table 1 Resistance for Thermistor Temperature 25 ...
Страница 36: ...36 10 DIAGNOSTIC TEST 35 T ...
Страница 60: ...60 13 EXPLODED VIEW 13 1 Control Panel and Plate Assembly A210 A211 A120 A140 A110 58 ...
Страница 65: ...65 MAY 2018 PRINTED IN KOREA P No MFL69290420 ...