20
This feature allows you to quickly verify that the exhaust system is adequate for the normal function of the
dryer. The check takes only two minutes. The results of the check are displayed in the FlowSense
TM
display window as shown below
(Fig. 1). The dryer must be at room temperature for this test to be reliable. To perform this test, start the
machine in standby mode (power off). Press and hold both the
SIGNAL ON/OFF
and the
TEMP CONTROL
buttons together while turning on the dryer with the POWER button. The dryer will start and run for 3 minutes
while it checks temperatures. At the end of this short cycle, it will display the results as follows.
1. Press and hold the SIGNAL ON/OFF and TEMP.
CONTROL button and then press the POWER button.
This button sequence activates the installation test. The
code will display if the activation is successful.
3. Check the display for results.
During the two minute test cycle, monitor the
FLOW SENSE
TM
display on the control panel.
If no bars are displayed, when the cycle ends,
the exhaust system is adequate. If the exhaust
system is severely restricted, the display will
show four bars. Other problems may also be
shown with error codes. Refer to the next page
for error code details and solutions.
4. END of Cycle.
At the end of the test cycle, will display.
The test cycle will end and the dryer will shut off
automatically after a short delay.
NO BARS:
OK
FOUR BARS:
RESTRICTED
2. Press START/PAUSE button.
The dryer will start the test, which will last about two
minutes. The heater will be turned on and the
temperatures in the drum will be measured.
8-2 Installation check
Error Code
tE1
or
tE2
HS
PS or PF or nP
Possible Causes
Temperature sensor failure
Turn off the dryer and call for service.
Turn off the dryer and call for service.
Check the power supply or the connection of power
cord to the terminal block. Refer to the Connecting
Electric Dryers section of this manual for complete
instructions.
Reset circuit breaker or replace fuse. Do not increase
the fuse capacity. If the problem is a circuit overload,
have it corrected by a qualified electrician.
Humidity Sensor failure
Electric dryer power cord is not
connected correctly, or house
power supply is incorrect.
House fuse is blown, circuit
breaker has tripped, or power
outage has occurred.
Solutions