![LG DLE2250 Series Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/lg/dle2250-series/dle2250-series_service-manual_210650015.webp)
15
Component
Test Procedure
Check result
Remark
7. Heater
Measure resistance of the
following terminal
Terminal: 1 (COM) - 2
Terminal: 1 (COM) - 3
Terminal: 2 - 3
Resistance value: 10W
Resistance value: 10W
Resistance value: 20W
¥ Electric type
8. Thermistor
Measure resistance of terminal
to terminal
Temperature condition:
58¡F ~ (10~40¡C)
58¡F ~ 104F (10~40¡C)
Resistance value: 10W
¥ Heater case -
Hi limit
¥ Electric type
9. Motor
¥ See Page 17
10. Gas valve
valve 1
valve 2
Measure resistance of the
following terminal
Valve 1 terminal
Valve 2 terminal
Resistance value: > 1.5 kW
Resistance value: > 1.5~2.5 kW
¥ Gas type
12. Flame Detect
Measure resistance of terminal
to terminal
Open at 370¡F ((Maximum)
Close at 320¡F
Resistance value
≒
¥
Resistance value < 1W
¥ Gas type
11. Igniter
5318EL3001
MEQ61841001
Measure resistance of terminal
to terminal
Resistance value
100~800 W
(for 5318EL3001)
40-150 W
(for MEQ1841001)
á Gas type