13
13. Outlet Thermostat
(Auto reset)
14. Outlet Thermostatt
(Manual reset)
Measure resistance of terminal
to terminal
Open at 203
7 F (95
5 C
Close at 159
9 F (70
5 C)
Gas type
Gas funnel
Gas type
Electric type
Gas funnel
Measure resistance of terminal
to terminal
Open at 212
12 F
(110
7 C)
Manual reset
If thermal fuse is open must
be replaced
Resistance value
Continuity <
1
Ω
Check Top Marking:
N95
Check Top Marking:
N110
Resistance value
Continuity <
1
Ω
Component Test Procedure Check result
Remark
15. Inlet. valve
Measure resistance of the
Following terminal
Left picture
-.plate