22
Connecting Gas Dryers (cont.)
w
WArNiNg
To reduce the risk of fire, electric shock, or injury
to persons when using this appliance, follow basic
precautions, including the following:
• Installation and service must be performed by
a qualified installer, service agency, or the gas
supplier. Failure to do so can result in fire, explosion,
or death.
• Use only a new stainless steel flexible connector
and a new AGA-certified connector. Failure to do so
can result in fire, explosion, or death.
• A gas shutoff valve must be installed within 6 ft.
(1.8 m) of the dryer. Failure to do so can result in fire,
explosion, or death.
• The dryer is configured for LP(Liquefied Propane)
Gas when shipped from the factory. Make sure
that the dryer is equipped with the correct burner
orifice for the type of gas being used (Natural Gas
or Liquefied Petroleum). Failure to do so can result in
fire, explosion, or death.
• If necessary, the correct orifice (For the Natural
orifice kit, order part number 383EEL3002K) should
be installed by a qualified technician and the
change should be noted on the dryer. Failure to do
so can result in fire, explosion, or death.
• All connections must be in accordance with local
codes and regulations. Failure to do so can result in
fire, explosion, or death.
• Gas dryers MUST exhaust to the outdoors. Failure to
do so can result in fire, explosion, or death.
connecting the gas supply
1. Make sure that the gas supply to the laundry room is
turned OFF. Confirm that the type of gas available in
your laundry room is appropriate for the dryer. The
dryer is prepared for LP(Liquefied Propane) Gas with a
3
⁄₈ - inch NPT gas connection.
2. Remove the shipping cap from the gas connection
at the back of the dryer. Be careful not to damage
the threads of the gas connector when removing the
shipping cap.
3. Connect the dryer to your laundry room’s gas supply
using a new flexible stainless steel connector with a
3
⁄₈
- inch NPT fitting.
4. Securely tighten all connections between the
dryer and your laundry room’s gas supply. Turn on
your laundry room’s gas supply and check all pipe
connections (both internal and external) for gas leaks
with a noncorrosive leak-detection fluid.
electrical connection
Plug dryer into a 120 V~
60 Hz grounded 3-prong
outlet.
Gas Supply
Shutoff Valve
AGA/CSA-
Certified Stainless
Steel Flexible
Connector
3/8
→
5/16
NPT coupling
(from dryer to
hose – gas tank)
3/8
→
1/2 NPT
coupling (from
dryer to pipe
–gas pipe)
high-altitude installations
The BTU rating of this dryer is AGA-certified for
elevations below 10,000 feet.
If your gas dryer is being installed at an elevation above
10,000 feet, it must be derated by a qualified technician
or gas supplier.
iNSTALLATiON iNSTruCTiONS
MFL69702003_en_170201.indd 22
2017.2.1 8:52:24 AM
Содержание DF VS Series
Страница 55: ...54 MFL69702003_en_170201 indd 54 2017 2 1 8 53 6 AM ...
Страница 109: ...54 MFL69702003_sp_170201 indd 54 2017 2 1 8 56 23 AM ...
Страница 110: ...55 ESPAÑOL MFL69702003_sp_170201 indd 55 2017 2 1 8 56 23 AM ...
Страница 111: ...56 MFL69702003_sp_170201 indd 56 2017 2 1 8 56 23 AM ...
Страница 112: ...57 ESPAÑOL MFL69702003_sp_170201 indd 57 2017 2 1 8 56 23 AM ...
Страница 113: ...58 MFL69702003_sp_170201 indd 58 2017 2 1 8 56 23 AM ...
Страница 114: ...59 ESPAÑOL MFL69702003_sp_170201 indd 59 2017 2 1 8 56 23 AM ...
Страница 115: ...60 MFL69702003_sp_170201 indd 60 2017 2 1 8 56 23 AM ...
Страница 116: ...61 ESPAÑOL MFL69702003_sp_170201 indd 61 2017 2 1 8 56 24 AM ...
Страница 117: ...MFL69702003_sp_170201 indd 62 2017 2 1 8 56 24 AM ...