SHIPPING INSPECTION
This product was carefully inspected at the factory and released to the transportation company with no known
damage. Inspect carton for damage to help locate potential areas of damage. Remove carton and inspect entire
unit for damage. If damage is found, report it immediately to the carrier.
UNIT DIMENSIONS
Physical Data, 12 SEER Models
12"
12"
6"
60"
SIDE VIEW
TOP VIEW
Fig. 1
C
B
A
A
B
C
1.5 Ton
24
21
/
32
22
11
/
16
27
11
/
16
2.0 Ton
24
21
/
32
22
11
/
16
27
11
/
16
2.5 Ton
24
21
/
32
22
11
/
16
27
11
/
16
3.0 Ton
24
21
/
32
22
11
/
16
27
11
/
16
3.5 Ton
28
27
32
5
/
8
4.0 Ton
28
27
32
5
/
8
5.0 Ton
-
-
-
Table 1
MINIMUM CLEARANCES (SEE FIGURE 1)
• 30" clearance to service panel
• 6" clearance to one side of the unit.
• 12" clearance to two other sides of unit.
• 24" Clearance between two condensing units.
• 60" clearance above unit.
INSTALLATION LOCATION
•Away from windows
• Do not install under gas appliance vent
• At least 36" away from clothes dryer vent
• On a solid, level pad
• Isolated from the building structure (Avoid vibration
transmission)
REMOVING EXISTING CONDENSING
UNIT
• Warning! Electrical shock can cause severe
injury or death. Use disconnect switch to dis-
connect power to unit.
• Warning! Recover all refrigerant from prior
unit to avoid personal injury or death.