11. AUTO CALIBRATION
- 116 -
Screen
>
Cable loss : Enter the RF cable loss GSM and DCS
Screen
>
GPIB(Primary address) : Enter the SS(Ag8960) and PS(Tektronix PS2521G) GPIB address
Screen
>
ADC Channel : Default ADC Calibration Channel
Screen
>
Auto Calibration Item : Default Calibration Settings about Tx, Rx, ADC and write BIN file
11.4 AGC
This procedure is for Rx calibration.
In this procedure, We can get RSSI correction value. Set band EGSM and press Start button the result
window will show correction values per every power level and gain code and the same measure is
performed per every frequency.
11.5 APC
This procedure is for Tx calibration.
In this procedure you can get proper scale factor value and measured power level.
Figure 11-1. Auto Calibration Program