![LG BUEL011HBC1 Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/lg/buel011hbc1/buel011hbc1_installation-manual_207175042.webp)
Appendix
42
Code
Message
Description
Solution
695
Over Charge Power
Limit Warning
Charge Power level is higher than
the limit
Automatically released after
warning condition is cleared
697
ADC Interrupt
Warning
Warning of the MCU AD interrupt
operation
Automatically released after
warning condition is cleared
701
Safety CRC Check
Error
Warning of the safety memory
range CRC data
Automatically released after
warning condition is cleared
702
Cell Over Voltage
Fault1
Cell Voltage level of battery cell is
higher than the limit
Automatically restart after
fault condition is cleared
703
Cell Under Voltage
Fault1
Cell Voltage level of battery cell is
lower than the limit
Contact service center
705
Unit Over voltage
Fault1
Unit Voltage level of battery cell is
higher than the limit
Automatically restart after
fault condition is cleared
706
Unit Under voltage
Fault1
Unit Voltage level of battery cell is
lower than the limit
Automatically restart after
fault condition is cleared
707
Unit Voltage ADC
Mux Fault1
Unit voltage AD conversion
multiplex fault
Automatically restart after
fault condition is cleared
710
Discharge Over
Temperature Fault1
Discharge temperature level is
higher than the limit
Automatically restart after
fault condition is cleared
711
Discharge Under
Temperature Fault1
Discharge temperature level is
lower than the limit
Automatically restart after
fault condition is cleared
712
Charge Over
Temperature Fault1
Charge temperature level is higher
than the limit
Automatically restart after
fault condition is cleared
713
Charge Under
Temperature Fault1
Charge temperature level is lower
than the limit
Automatically restart after
fault condition is cleared
714
Terminal Over
Temperature Fault1
Power Terminal temperature level
is higher than the limit
Automatically restart after
fault condition is cleared
718
Discharge Over
Current Fault1
Discharge current level is higher
than the limit
Automatically restart after
fault condition is cleared
719
Charge Over Current
Fault1
Charge current level is higher than
the limit
Automatically restart after
fault condition is cleared
721
Atmosphere
Discharge Over
Temperature Fault1
Discharge Atmosphere
temperature level is higher than
the limit
Automatically restart after
fault condition is cleared
722
Atmosphere
Discharge Under
Temperature Fault1
Discharge Atmosphere
temperature level is lower than the
limit
Automatically restart after
fault condition is cleared
723
Atmosphere Charge
Over Temperature
Fault1
Charge Atmosphere temperature
level is higher than the limit
Automatically restart after
fault condition is cleared
Содержание BUEL011HBC1
Страница 46: ...Appendix 46 Wiring Diagram BUEL011HBC1 Pack 3 BCU Enclosure BUEL015HBC1 Pack 4 BCU Enclosure ...
Страница 47: ...Appendix 47 ...
Страница 48: ......
Страница 93: ...Anhang 45 Elektroschaltplan BUEL011HBC1 Paket 3 BCU Gehäuse BUEL015HBC1 Paket 4 BCU Gehäuse ...
Страница 94: ......
Страница 139: ...Apéndice 45 Diagrama de cableado BUEL011HBC1 3 baterías BCU carcasa BUEL015HBC1 4 baterías BCU carcasa ...
Страница 140: ......