- 113 -
11. AUTO CALIBRATION
11. AUTO CALIBRATION
11.1 Overview
Autocal(Auto Calibration) is the PC side Calibration tool that performTx,Rx and Battery
Calibration with Agilent 8960(GSM call setting instrument) and Tektronix
PS2521G(Programmable Power supply). Autocal generate calibration data by communicating
with phone and measuring equipment then write it into calibration data block of flash memory in
GSM phone.
11.2 Requirements
-PC or Notebook installed with Microsoft Windows 98/ME/2000/XP
-Auto Calibration program(Autocal.exe)
-GSM Phone
-LGE PIF JIG, Serial Cable, Data Cable
-Agilent 8960(Call Setting Instrument)
-Tektronix PS2521G(Programmable Power Supply)
11.3 Menu and Settings
-File(F) Clear View : Clear Calibration Status window texts
-File(F) Save View : Save Calibration Status window texts
-File(F) Save Setting : Save Current Calibration settings to setting file(*.cal)
-File(F) Load Setting : Load saved Calibration setting
-File(F) Make BIN ALL : Make binary file after calibration finished
-File(F) Make BIN BAT.Cal only : Make binary file of battery cal data only after calibration
finished
-File(F) Make & Write BIN : Make binary file after calibration finished then download it to
the Flash Memory
-View(V) Tools : Enable or disable Tool bar
-View(V) Status : Enable or disable status bar
-Connection(C) Connect : Connect the phone with PC. This procedure checks whether the PC
isconnected “8960” or not. After that it performs sync. procedure with-
phone. If the sync. procedure is successful state column on status
barchanged to SETUP, else you should disconnect phone and try
againfrom the beginning and alsocheck the whole connection.
Allmeasurement is performed atstate SETUP.
-Connection(C) Port Setting : Show COM port setting dialog and Baudrateyou can change,etc.
-GPIB(G) Connect : Connect the Ag8960 GPIB card with PC.
Содержание B2050
Страница 7: ... 6 2 PERFORMANCE 2 PERFORMANCE 2 1 H W Features ...
Страница 8: ... 7 2 PERFORMANCE ...
Страница 9: ... 8 2 PERFORMANCE 2 2 Technical Specification ...
Страница 10: ... 9 2 PERFORMANCE ...
Страница 11: ... 10 2 PERFORMANCE ...
Страница 12: ... 11 2 PERFORMANCE ...
Страница 13: ... 12 2 PERFORMANCE ...
Страница 53: ... 52 4 2 TX Trouble TEST POINT 13Mhz OSCILLATOR Mobile SW FEM TRANCEIVER LDO PAM 4 TROUBLE SHOOTING ...
Страница 57: ... 56 3 Checking Ant SW Mobile SW 4 TROUBLE SHOOTING ...
Страница 67: ... 66 TEST POINT 4 6 LCD Trouble 4 TROUBLE SHOOTING ...
Страница 70: ... 69 4 TROUBLE SHOOTING TEST POINT 4 7 Speaker Trouble ...
Страница 77: ... 76 4 TROUBLE SHOOTING 4 10 KEY backlight Trouble TEST POINT ...
Страница 91: ... 90 5 DOWNLOAD AND CALIBRATION 6 Press Start and Pover on the phone using JIG remote Power on Switch 1 ...
Страница 92: ...5 DOWNLOAD AND CALIBRATION 91 5 2 Calibration ...
Страница 93: ... 92 5 DOWNLOAD AND CALIBRATION ...
Страница 97: ......
Страница 103: ... 102 Figure 8 1 B2050 BOTTOM SIDE PCB LAYOUT 8 PCB LAYOUT ...
Страница 104: ... 103 8 PCB LAYOUT Figure 8 1 B2050 TOP SIDE PCB LAYOUT ...
Страница 105: ......
Страница 113: ...10 STAND ALONE TEST 112 ...
Страница 117: ......
Страница 119: ......
Страница 132: ... 131 ...
Страница 133: ... 132 ...