NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Codes & Approvals

C

ertifiCation

Gas appliances must be tested and certified by a nation-

ally recognized testing and certification laboratory to ANSI 

(American National Standard Institute) gas appliance safety 

standards.

This  insert  has  been  tested  and  certified  by  OMNI  -Test 

Laboratories  to  ANSI  Z21.88-2005  Standard  for  Vented 

Gas Fireplace Heaters and UL 307B Gas Burning Heating 

Appliances for Manufactured (Mobile) Homes.

It has met all necessary ANSI Standards and is fully certified 

for installation in any community. If there are any questions 

or if you need further substantiation either write to or call 

your Lennox Hearth Products dealer. If you have further 

questions, please contact Lennox Hearth Products.

n

ew

 y

ork

 C

ity

, n

ew

 y

ork

 (mea)

Installation of these fireplaces are approved for installa-

tion in New York City in the US state of New York (MEA#:  

138-07-E).

C

ommonwealth

 o

f

 m

assaChusetts

 r

equirements

Installation of these fireplaces are  approved  for installation 

in the US state of Massachusetts if the following additional 

requirements are met - 

•  Installation and repair must be done by a plumber or gas 

fitter licensed in the Commonwealth of Massachusetts.

•  The flexible gas line connector used shall not exceed 36 

inches (92 centimeters) in length.

•  The individual manual shut-off must be a T-handle type 

valve.

Orifice Size/Altitude Adjustment

For altitudes above 2,000 feet, the orifice should be de-rated 

by 4% for every 1,000 feet to maintain the proper ratio of 

gas  to  air.  Improper  orifice  sizing  may  result  in  damage 

and unsafe conditions. Changing the orifice should only be 

done by a qualified service technician. Contact your Lennox 

Hearth Products dealer for proper orifice sizes (see Page 21 

and 24 for more information).

The Firestar™ Insert

•  Must conform with all local, state, and national installation 

codes. In the absence of local codes, the installation must 

conform with National Fuel Gas Code ANSI Z223.1 - latest 

edition, also known as NFPA 54. Refer to the National 

Fuel Gas Code and local zoning and code authorities for 

details on installation requirements.

•  Must conform with the Manufactured Home Construc-

tion  and  Safety  Standard,  Title  24  CFR,  Part  3280,  or 

when such a standard is not applicable, the Standard for 

Manufactured Home Installations, ANSI A225.1 - latest 

edition for manufactured (mobile) home installations.

•  Must be vented directly to the outside in accordance with 

the latest edition of the National Fuel Gas Code and must 

never be attached to a chimney serving a separate solid 

fuel burning appliance.

•  Uses room air for combustion. It is imperative that provi-

sions for adequate combustion and ventilation air be made. 

This appliance is NOT designed to and will not operate in 

a negative pressure. Contact your dealer if you suspect 

such a situation exists.

•  Has been certified for use with either natural gas or pro-

pane.

•  Is not for use with solid fuels.

•  Is approved for sitting rooms and/or bedrooms.

Fireplace Requirements

These heaters are designed to be installed into an existing 

masonry fireplace (built to UBC 37 standards) or factory 

built solid fuel, wood burning fireplace (listed to UL 127 

standards) only. All exhaust gases must be vented outside 

the structure. Combustion air is drawn from outside the 

structure. When installing in a factory built fireplace, the 

fireplace grate must be removed and the damper must be 

removed or secured open.

If the factory-built fireplace has no gas access hole(s) pro-

vided, an access hole of 1-1/2 inches (38 mm) or less may 

be drilled through the lower sides or bottom of the firebox 

in a proper workmanship like manner. This access hole must 

be plugged with a non-combustible insulation after the gas 

supply line has been installed. 

The installer must mechanically attach the marking supplied 

with the gas fireplace insert to the inside of the firebox of the 

fireplace into which the gas fireplace insert is installed.

IMPORTANT: When installing these appliances into a fac-

tory built fireplace or heat-form, the air flow within and 

around the fireplace shall not be altered by the installation 

of the insert (i.e. DO NOT BLOCK louvers or cooling air 

inlet or outlet ports, circulating air chambers in a steel 

fireplace liner or metal heat circulator). 

WARNING

THIS FIREPLACE HAS BEEN ALTERED TO 

ACCOMMODATE A FIREPLACE INSERT AND 

SHOULD BE INSPECTED BY A QUALIFIED 

PERSON PRIOR TO RE-USE AS A 

CONVENTIONAL FIREPLACE.

Содержание B-VENT GAS GC3

Страница 1: ...structions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incendies L installation et l entretien doivent être assurés par un installateur ou un service d entretien qualifié ou par le fournisseur de gaz WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life AVE...

Страница 2: ... Line Installation 11 Gas Pressure Requirements 11 Gas Supply Line Sizing 11 LP Natural Gas Supplies 12 Air Shutter Adjustment 12 Operating Instructions 13 16 Pre Lighting Checklist 13 Lighting Instructions 13 Flame Color Behavior 14 Replacing Burner Orifices 14 Paint Curing 15 Quiet Operation 15 Blower 15 On Off Switch And Thermostat 15 Pilot Adjustment 15 Millivolt Control System 16 Maintenance ...

Страница 3: ...lations ANSIA225 1 latest edition The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition Your Lennox gas insert must be equipped for the proper fuel type altitude at which it will be operated Any operation outside the parameters outlined in this manual may result in a h...

Страница 4: ...requirements Must conform with the Manufactured Home Construc tion and Safety Standard Title 24 CFR Part 3280 or when such a standard is not applicable the Standard for Manufactured Home Installations ANSI A225 1 latest edition for manufactured mobile home installations Must be vented directly to the outside in accordance with the latest edition of the National Fuel Gas Code and must never be atta...

Страница 5: ...kaging List To install a Firestar insert an insert body and surround flange kit are required Insert Body Packaging List 1 Insert Body with Burner Cassette and trivet 1 Set of Refractory Brick Panels 3 pieces H5866 1 Log Set H5860 1 Lower front 2 filler panel 1 Fasteners 6 slotted 1 4 truss screws 4 speed nuts 6 spring clips 4 3 8 x 3 leveling bolts 2 socket head screws 1 Installation and Operation...

Страница 6: ...rebox must accept the insert withoutmodificationotherthanremovingbolted or screwed together pieces such as baffles smoke shelf deflectors ash lips glass door screen or door tracks log grates refractory or masonry lining and damper assemblies Any fireplacecomponent whichisremoved mustbe retainedsotheycanbereinstalledtorestorethe fireplace to its original operating condition The removal of any part ...

Страница 7: ...height the nut previously threaded onto the bolt can be snugged up to the insert bottom Hearth Floor Protection Minimum Clearances to Combustibles The letters below C through H correspond to Figure 4 showing minimum clearances required from the appliance to combustibles and the minimum projection of the hearth extension C 6 5 to Side Facing 3 4 or less D 11 to Side Wall E 24 to Mantel more than 3 ...

Страница 8: ...ons for installation and vent termination A minimum flue height of 12 feet is recommended The insert must be installed so the draft hood is in the same atmospheric pressure zone as the combustion air inlet to the appliance Flue Collar Connection This insert has a detachable flue collar to ease installation To detach flue collar lift removable vent trivet from top of insert unscrew draft tube retai...

Страница 9: ...x Tilt the top of the panel forward insert the bottom of the panel in the brick panel retainer and push the panel to the up right position 3 Install the side panels by sliding the top of the panel into the top side brick retainer and then dropping the bottom of the panel into the bottom retainer The rounded edge on the side brick panels goes toward the front 3 Piece Brick Panel Set Log Installatio...

Страница 10: ...ews after shifting flanges to eliminate space between side and top flanges 5 Install two spring clips approximately five inches from each end of each of the three gold trim pieces The spring clips shouldbeinstalledinthechannelofthetrimwiththecurved end to the front toward the rounded surface of the trim 6 Place the longest trim piece with the rounded surface out along the edge of the top flange wi...

Страница 11: ...ing The proper gas line diameter must be selected to run from the supply regulator to the insert Refer to the Table 2 for proper gas pipe diameters NOTE Someareasallowcoppertubing checkwithlocalapproval agencies and codes COPPER TUBING NOT ALLOWED IN MASSACHUSETTS IN NATURAL GAS INSTALLATIONS NEVER USE GALVANIZED OR PLASTIC PIPES Fuel Type Inlet Pressure Manifold Pressure Desired Minimum Maximum O...

Страница 12: ...ss logs or heat exchanger If soot begins to form after burning the air shutter should be opened gradually until the sooting conditionstops Opentheshutterasmallamountatatime untilthesootingceases See FlameColorandBehavior and Maintenance proper pilot flame 1 Remove glass door see Glass Door Removal on page 17 Carefully remove the log set and set aside 2 Using a 5 32 allen wrench remove the allen he...

Страница 13: ...b will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D DONOTusethisapplianceifanyparthasbeenunderwater Immediately call a qualified service technician to inspect theapplianceandtoreplaceanypartofthecontrolsystem and any gas control which has been under water OPERATING INSTRUCTIONS Refer to controls...

Страница 14: ...e color Adjusting the insert to cause the flames to turn orange sooner may result in poor combustion sooting and a hazardous situation See Figure 17 showing proper flame appearance OFF ON PiezoIgniter ON OFFSwitch No Blue Flame Center Soot at Flame Tip Dark Orange Flame IMPROPERLY BURNING FLAME Soot above Flame Tip No Soot at Flame Tip PROPERLY BURNING FLAME Semi Transparent Yellow Flame Blue Flam...

Страница 15: ...behind the right side door to the right of the control valve This switch can be relocated to the hole provided in the top surround panel by pulling the two connectors off of the spades on the back of the switch Then unscrew the plastic nut on the back side of the switch and pull the switch forward through the hole Cut the wire tie holding the switch wire and feed the wire behind the side flange up...

Страница 16: ... thermostat Additional switches may affect the system resistance and increase the chance of the burner not ignit ing Follow the instructions included with the thermostat or remote control for wiring The thermostat remote control and rocker switch will turn theburneronandoffindependently Besuretosettherocker switch to the OFF position when using the thermostat or remote control and set the thermost...

Страница 17: ...lass DONOTcleandoororglasswhenhot DO NOT abuse the glass door by striking or slamming it shut DO NOT use substitute materials if replacing the glass DO NOT spray commercial glass cleaner with ammonia on the door and glass gasket as it may dissolve the gasket glue Replacement Theglassintheinsertdoorcannotbereplaced separately Should the glass be damaged the entire glass gasket and metal frame assem...

Страница 18: ...en servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing See the fan wiring diagram below for reference Remove the glass door log set and brick pan els All of these items are fragile so handle them with care Remove the two allen head screws at the left and right front of the air control panel and lift the panel out Next remove the nine ...

Страница 19: ...g the burner gently through the block plate and past the pilot assembly 4 Disconnect at the valve the two wire connectors from vent safety snap switch the uppermost black wire on terminal 1 and the black wire with the round connector located at the top of the valve and behind the gas inlet elbow Then disconnect the thermostat red and white wires and rocker switch black wires at terminals 1 3 5 Rem...

Страница 20: ...lem if longer purge will not light check gap between electrode and pilot should be 1 8 inch 3 mm to have a strong spark If OK replace pilot Pilot will not stay lit after carefully following lighting instructions 1 Vent Safety Snap Switch shut down 2 Improper Flame impingement 3 Low gas inlet pres sure 4 Defective thermopile 5 Bad connection 6 Defective automatic valve operator 1 Snap switch activa...

Страница 21: ...Ft for each door 75146 Gold Door w Glass H5875 Heat Sensed Blower Snap Switch H3106 Left hand Side Door Mounting Brackets Blower Speed Control Installed H5881 LP Pilot Assembly Includes Thermopile Electrode And Wire H5930 LP Pilot Orifice H5940 LP Regulator H5744 Main Burner On Off Rocker Switch H5995 Main Burner On Off Switch Wires H5981 Main Door Decorative Gold Bars Each 2 Per Stove H5982 Main ...

Страница 22: ...22 Safety Listing Label ...

Страница 23: ...23 Lighting Label ...

Страница 24: ...etain this manual File it with your other documents for future refer ence Product reference information We recommend that you record the following important information about your fireplace Please contact your Lennox Hearth Products dealer for any questions or concerns For the number of your nearest Lennox Hearth Products dealer please call 1 800 9 Lennox Replacement parts See Page 21 for a comple...

Отзывы: