NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

 

FOR YOUR SAFETY do not install or operate your Fire-

star™ gas insert without first reading & understanding 

this manual. Any installation or operation of the appli-

ance deviating from that which is stated in this manual 

WILL void the warranty & may be hazardous.

 

INSTALLATION & REPAIR SHOULD ONLY BE DONE BY 

A QUALIFIED SERVICE TECHNICIAN. DO NOT ATTEMPT 

TO SERVICE THE APPLIANCE YOURSELF.

 

The insert should be inspected & cleaned before use 

& at least annually by a qualified service technician. 

More frequent cleaning may be required due to exces-

sive lint from bedding material, carpeting, etc.

 

It is imperative that control compartments, burners, & 

circulating air passageways of the room heater be kept 

clean.

 Adequate clearances around the combustion chamber 

and  accessibility  clearances  for  servicing  &  proper 

operation must be maintained.

 

Turn off the gas before servicing this appliance. It is  

 recommended that a qualified service technician per-

form an appliance check-up at the beginning of each 

heating season.

 

All installations must conform with all local, state, & 

national codes. In the absence of local codes, the instal-

lation must conform with National Fuel Gas Code ANSI 

Z.1-latest edition, also known as NFPA 54. Refer 

to the National Fuel Gas Code & local zoning & code 

authorities  for  details  on  installation  requirements. 

Your Firestar gas insert must be vented to the outside 

in accordance with the latest edition of the National 

Fuel Gas Code.

 

This gas insert MUST be vented directly to the outside 

& MUST NEVER be attached to a chimney serving a 

separate solid fuel burning appliance. Each gas appli-

ance MUST USE a separate vent system. Common vent 

systems are PROHIBITED.

 

This appliance uses room air for combustion.  It is im-

perative that provisions for adequate combustion and 

ventilation air be made.  This appliance is NOT designed 

to and will not operate in a negative pressure. Contact 

your dealer if you suspect such a situation exists.

 

Mobile home installations must conform with the Mobile 

Home Construction and Safety Standard, Title 4 CFR, 

Part 80, or, when such a standard is not applicable, 

the Standard for Mobile Home Installations, ANSI A5.1 

- latest edition.

 

The  appliance,  when  installed,  must  be  electrically 

grounded  in  accordance  with  local  codes  or  in  the 

absence  of  local  codes,  with  the  National  Electrical 

Code, ANSI/NFPA 70 - latest edition. 

 

Your  Lennox™  gas  insert  must  be  equipped  for  the 

proper fuel type & altitude at which it will be operated. 

Any operation outside the parameters outlined in this 

manual may result in a hazardous condition & will void 

the warranty. Please carefully read the sections pertain-

ing to these subjects and/or be sure your appliance is 

properly equipped.

 Do not use this insert if any part has been under water. 

Immediately call a qualified service technician to inspect 

the appliance & to replace any part of the control system 

& any gas control which has been under water.

 Due to high temperatures, the insert should be located 

out  of  traffic  areas  &  away  from  furniture  &  draper-

ies.

 Children & adults should be alerted to the hazards of 

high surface temperature & should stay away to avoid 

burns or clothing ignition. Young children should be 

carefully supervised when they are in the same room as 

the Lennox gas insert. Clothing or any other flammable 

material should not be placed on or near the insert.

 Never use solid fuels such as wood, paper, cardboard, 

coal,  or  any  flammable  liquids,  etc.,  in  this  appli-

ance.

 

Any grill, panel, or glass removed for service MUST be 

replaced prior to operating the insert. Do not operate 

appliance  with  the  glass  front  removed,  cracked  or 

broken. Replacement of the glass should be done by a 

qualified service technician.

 DO NOT USE abrasive cleaner on the glass door assem-

bly. DO NOT ATTEMPT to clean the glass door when it 

is hot.

 Gold & nickel plated surfaces must be cleaned with 

glass cleaner & a clean soft cloth before firing the first 

time or fingerprints will remain permanently. NEVER use 

brass polish to clean gold or nickel, this will remove 

the plating!!!

 When  opening  the  lower  door  on  the  face  while  the 

insert is burning, pull at the far left or far right vent 

openings, because the door is hot during operation.

 Lennox Hearth Products, its employees, or any of its 

representatives assume no responsibility for any dam-

ages caused by an inoperable, inadequate, or unsafe 

condition as a result of any improper operation, service 

or installation procedures, whether direct or indirect.

 INSTALLER:  THESE INSTRUCTIONS ARE TO REMAIN 

WITH THE HOME OWNER!

C

autions

 & s

afety

Содержание B-VENT GAS GC3

Страница 1: ...structions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incendies L installation et l entretien doivent être assurés par un installateur ou un service d entretien qualifié ou par le fournisseur de gaz WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life AVE...

Страница 2: ... Line Installation 11 Gas Pressure Requirements 11 Gas Supply Line Sizing 11 LP Natural Gas Supplies 12 Air Shutter Adjustment 12 Operating Instructions 13 16 Pre Lighting Checklist 13 Lighting Instructions 13 Flame Color Behavior 14 Replacing Burner Orifices 14 Paint Curing 15 Quiet Operation 15 Blower 15 On Off Switch And Thermostat 15 Pilot Adjustment 15 Millivolt Control System 16 Maintenance ...

Страница 3: ...lations ANSIA225 1 latest edition The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition Your Lennox gas insert must be equipped for the proper fuel type altitude at which it will be operated Any operation outside the parameters outlined in this manual may result in a h...

Страница 4: ...requirements Must conform with the Manufactured Home Construc tion and Safety Standard Title 24 CFR Part 3280 or when such a standard is not applicable the Standard for Manufactured Home Installations ANSI A225 1 latest edition for manufactured mobile home installations Must be vented directly to the outside in accordance with the latest edition of the National Fuel Gas Code and must never be atta...

Страница 5: ...kaging List To install a Firestar insert an insert body and surround flange kit are required Insert Body Packaging List 1 Insert Body with Burner Cassette and trivet 1 Set of Refractory Brick Panels 3 pieces H5866 1 Log Set H5860 1 Lower front 2 filler panel 1 Fasteners 6 slotted 1 4 truss screws 4 speed nuts 6 spring clips 4 3 8 x 3 leveling bolts 2 socket head screws 1 Installation and Operation...

Страница 6: ...rebox must accept the insert withoutmodificationotherthanremovingbolted or screwed together pieces such as baffles smoke shelf deflectors ash lips glass door screen or door tracks log grates refractory or masonry lining and damper assemblies Any fireplacecomponent whichisremoved mustbe retainedsotheycanbereinstalledtorestorethe fireplace to its original operating condition The removal of any part ...

Страница 7: ...height the nut previously threaded onto the bolt can be snugged up to the insert bottom Hearth Floor Protection Minimum Clearances to Combustibles The letters below C through H correspond to Figure 4 showing minimum clearances required from the appliance to combustibles and the minimum projection of the hearth extension C 6 5 to Side Facing 3 4 or less D 11 to Side Wall E 24 to Mantel more than 3 ...

Страница 8: ...ons for installation and vent termination A minimum flue height of 12 feet is recommended The insert must be installed so the draft hood is in the same atmospheric pressure zone as the combustion air inlet to the appliance Flue Collar Connection This insert has a detachable flue collar to ease installation To detach flue collar lift removable vent trivet from top of insert unscrew draft tube retai...

Страница 9: ...x Tilt the top of the panel forward insert the bottom of the panel in the brick panel retainer and push the panel to the up right position 3 Install the side panels by sliding the top of the panel into the top side brick retainer and then dropping the bottom of the panel into the bottom retainer The rounded edge on the side brick panels goes toward the front 3 Piece Brick Panel Set Log Installatio...

Страница 10: ...ews after shifting flanges to eliminate space between side and top flanges 5 Install two spring clips approximately five inches from each end of each of the three gold trim pieces The spring clips shouldbeinstalledinthechannelofthetrimwiththecurved end to the front toward the rounded surface of the trim 6 Place the longest trim piece with the rounded surface out along the edge of the top flange wi...

Страница 11: ...ing The proper gas line diameter must be selected to run from the supply regulator to the insert Refer to the Table 2 for proper gas pipe diameters NOTE Someareasallowcoppertubing checkwithlocalapproval agencies and codes COPPER TUBING NOT ALLOWED IN MASSACHUSETTS IN NATURAL GAS INSTALLATIONS NEVER USE GALVANIZED OR PLASTIC PIPES Fuel Type Inlet Pressure Manifold Pressure Desired Minimum Maximum O...

Страница 12: ...ss logs or heat exchanger If soot begins to form after burning the air shutter should be opened gradually until the sooting conditionstops Opentheshutterasmallamountatatime untilthesootingceases See FlameColorandBehavior and Maintenance proper pilot flame 1 Remove glass door see Glass Door Removal on page 17 Carefully remove the log set and set aside 2 Using a 5 32 allen wrench remove the allen he...

Страница 13: ...b will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D DONOTusethisapplianceifanyparthasbeenunderwater Immediately call a qualified service technician to inspect theapplianceandtoreplaceanypartofthecontrolsystem and any gas control which has been under water OPERATING INSTRUCTIONS Refer to controls...

Страница 14: ...e color Adjusting the insert to cause the flames to turn orange sooner may result in poor combustion sooting and a hazardous situation See Figure 17 showing proper flame appearance OFF ON PiezoIgniter ON OFFSwitch No Blue Flame Center Soot at Flame Tip Dark Orange Flame IMPROPERLY BURNING FLAME Soot above Flame Tip No Soot at Flame Tip PROPERLY BURNING FLAME Semi Transparent Yellow Flame Blue Flam...

Страница 15: ...behind the right side door to the right of the control valve This switch can be relocated to the hole provided in the top surround panel by pulling the two connectors off of the spades on the back of the switch Then unscrew the plastic nut on the back side of the switch and pull the switch forward through the hole Cut the wire tie holding the switch wire and feed the wire behind the side flange up...

Страница 16: ... thermostat Additional switches may affect the system resistance and increase the chance of the burner not ignit ing Follow the instructions included with the thermostat or remote control for wiring The thermostat remote control and rocker switch will turn theburneronandoffindependently Besuretosettherocker switch to the OFF position when using the thermostat or remote control and set the thermost...

Страница 17: ...lass DONOTcleandoororglasswhenhot DO NOT abuse the glass door by striking or slamming it shut DO NOT use substitute materials if replacing the glass DO NOT spray commercial glass cleaner with ammonia on the door and glass gasket as it may dissolve the gasket glue Replacement Theglassintheinsertdoorcannotbereplaced separately Should the glass be damaged the entire glass gasket and metal frame assem...

Страница 18: ...en servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing See the fan wiring diagram below for reference Remove the glass door log set and brick pan els All of these items are fragile so handle them with care Remove the two allen head screws at the left and right front of the air control panel and lift the panel out Next remove the nine ...

Страница 19: ...g the burner gently through the block plate and past the pilot assembly 4 Disconnect at the valve the two wire connectors from vent safety snap switch the uppermost black wire on terminal 1 and the black wire with the round connector located at the top of the valve and behind the gas inlet elbow Then disconnect the thermostat red and white wires and rocker switch black wires at terminals 1 3 5 Rem...

Страница 20: ...lem if longer purge will not light check gap between electrode and pilot should be 1 8 inch 3 mm to have a strong spark If OK replace pilot Pilot will not stay lit after carefully following lighting instructions 1 Vent Safety Snap Switch shut down 2 Improper Flame impingement 3 Low gas inlet pres sure 4 Defective thermopile 5 Bad connection 6 Defective automatic valve operator 1 Snap switch activa...

Страница 21: ...Ft for each door 75146 Gold Door w Glass H5875 Heat Sensed Blower Snap Switch H3106 Left hand Side Door Mounting Brackets Blower Speed Control Installed H5881 LP Pilot Assembly Includes Thermopile Electrode And Wire H5930 LP Pilot Orifice H5940 LP Regulator H5744 Main Burner On Off Rocker Switch H5995 Main Burner On Off Switch Wires H5981 Main Door Decorative Gold Bars Each 2 Per Stove H5982 Main ...

Страница 22: ...22 Safety Listing Label ...

Страница 23: ...23 Lighting Label ...

Страница 24: ...etain this manual File it with your other documents for future refer ence Product reference information We recommend that you record the following important information about your fireplace Please contact your Lennox Hearth Products dealer for any questions or concerns For the number of your nearest Lennox Hearth Products dealer please call 1 800 9 Lennox Replacement parts See Page 21 for a comple...

Отзывы: