18
OWNER'S INSTRUCTION
ENGLISH
Auto Changeover Mode - Setting the Mode Change Temperature
This Function is to set the operating mode of the Auto Changeover Mode.
NOTE
!
The Mode Change Temperature is the difference of temperature when from cooling mode
to heating mode or from heating mode to cooling mode.
Ex) V\/hen setting temperature is 25 °C(76 °F) and room temperature is 20 °C(68 °F), then
operating mode is heating. If you set the mode change temperature to 2 °C(4 °F), when
the room temperature up to 27 °C(25 °C + 2 °C)(80 °F(76 °F + 4 °F)), the unit start cool-
ing operation.
ln Auto Changeover Mode, Press FUNCTION button to select
Setting the Mode Change Temperature.
When function setting button is pressed, it repeats in the order of Auto Clean
→
Smart
Clean
→
Mode Change Temperature
→
Sub function setting mode clear
Press the TEMPERATURE SETTING button to set desired Mode Change Temperature.
(Default value is 2 °C(4 °F).)
Complete the setting by pressing SET/CLEAR button.
To raise the temperature
* Mode Change Temp. Range :
1~7 °C(2~14 °F)
To lower the temperature