Symptom
Check Point
1. Freezer room lamp
doesn’t work
1. Check the freezer door switch
2. Check the door S/W resistance
3. Check the LED Lamp
Resistance [Ω]
Door S/W
Normal
0
Push S/W
Infinity
Voltage [V]
CON6
15
th
pin ~ 17
th
pin
12V
LED Lamp
Voltage [V]
White ~ Yellow
Closed
0~2V
Open
12V
CON6
LED Lamp
LED Lamp
Door S/W
8-11. Freezer room lamp doesn’t work