- 33 -
6
Reconnect
Is the Connector Properly
connected?
No
Yes
7
Is the resistance value of Fuse
-M
less than 0.2Ω?
No
Yes
Change Fuse
- M
8
Is the resistance value of Heater
as follow?
No
Yes
Replace
Heater
9
Is the resistance value of defrost
sensor as follow?
Resistance is influenced by temperature.
Yes
Replace
Defrost
Sensor
No
10
Explain to customer
Measurement Point
Resistance [Ω]
(1)
105~117
CON7
19th pin ~ 20 th pin
Resistance [Ω]
23ºF /
-5ºC
38k
32ºF / 0ºC
30k
41ºF / 5ºC
24k
50ºF / 10ºC
19.5k
59ºF / 15ºC
16k
Fuse - M
Heater
Sensor