2008 Product Data
93
Flaring Work
Copper
pipe
90
°
Slanted Uneven Rough
14. Installation
The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a concrete
wall, use anchor bolts.
• Mount the installation plate horizontally by aligning
the centerline using a level.
2. Measure the wall and mark the centerline. It is also
important to use caution concerning the location of
the installation plate-routing of the wiring to power
outlets is through the walls typically. Drilling the
hole through the wall for piping connections must
be done safely.
Fixing Installation Plate
Installation Plate
Chassis
Hook
Type “A”
• Drill the piping hole with a ø70mm hole core drill.
Drill the piping hole at either the right or the left with
the hole slightly slanted to the outdoor side.
Main cause for gas leakage is due to defect in flaring
work. Carry out correct flaring work in the following
procedure.
Cut the pipes and the cable.
1. Use the piping kit accessory or the pipes purchased
locally.
2. Measure the distance between the indoor and the
outdoor unit.
3. Cut the pipes a little longer than measured distance.
4. Cut the cable 1.5m longer than the pipe length.
Drill a Hole in the Wall
5-7mm
(3/16"~5/16")
Indoor
WALL
Outdoor
Содержание AS-W0964GG1
Страница 1: ...5RMA2 01A Inverter Single 50Hz R410A ...
Страница 32: ...2008 Product Data 31 5 Dimensional drawings Indoor units 5 1 Indoor Units ...
Страница 33: ...32 2008 Product Data 5 Dimensional drawings Indoor units ...
Страница 34: ...2008 Product Data 33 5 Dimensional drawings Indoor units ...
Страница 35: ...34 2008 Product Data 5 Dimensional drawings Indoor units 45 140 Ø70 188 926 65 221 45 296 175 Ø70 ...
Страница 36: ...2008 Product Data 35 5 Dimensional drawings Indoor units ...
Страница 40: ...2008 Product Data 39 5 Dimensional drawings Outdoor units 1 5 2 Outdoor Units ...
Страница 41: ...40 2008 Product Data 5 Dimensional drawings Outdoor units 1 ...
Страница 46: ...2008 Product Data 45 6 Wiring diagrams Indoor Unit Models AS W096ADR0 AS W126ADR0 ...
Страница 48: ...2008 Product Data 47 6 Wiring diagrams Indoor Unit Models AS W1868 H1 Models AS W2463 H3 ...
Страница 49: ...48 2008 Product Data 6 Wiring diagrams Indoor Unit Models AS W2468 H1 ...
Страница 52: ...2008 Product Data 51 Models AS W096ADR0 AS W126ADR0 6 Wiring diagrams Outdoor units ...
Страница 54: ...2008 Product Data 53 6 Wiring diagrams Outdoor units Models AS W1865GG1 AS W1863 H3 Models AS W1868 H1 ...
Страница 55: ...54 2008 Product Data 6 Wiring diagrams Outdoor units Models AS W2463 H3 Models AS W2468 H1 AS W2465DH2 ...