32 Room Air Conditioner
Operation
■
Off-Timer <=> On-Timer Operation
•
When the set time is reached after the on/off time is input by the remote controller, the on/off-timer operation is
carried out according to the set time.
■
Sleep Timer Operation
•
When the sleep time is reached after <1,2,3,4,5,6,7,0(cancel) hr> is input by the remote controller while in appliance
operation, the operation of the appliance stops.
•
While the appliance is on pause, the sleep timer mode cannot be input.
•
While in cooling mode operation, 30 min later since the start of the sleep timer, the setting temperature increases by
1
°
C After another 30 min elapse, it increases by 1
°
C again.
•
When the sleep timer mode is input while in cooling cycle mode, the airflow speed of the indoor fan is set to the low.
•
When the sleep timer mode is input while in heating cycle mode, the airflow speed of the indoor fan is set to the
medium.
■
Chaos Swing Mode
•
By the Chaos Swing key input, the vane automatically operates with the Chaos Swing or they are fixed to the
desired direction.
■
Chaos Natural Wind Mode
•
When the Chaos Natural Wind mode is selected and then operated, the high, medium, or low speed of the air-
flow mode is operated for 2~15 sec randomly by the Chaos Simulation.
”
■
Jet Cool Mode Operation (C/O Model)
•
If the Jet Cool key is input at any operation mode while in appliance operation, the Jet Cool mode operates.
•
In the Jet Cool mode, the indoor fan is operated at super-high speed for 30 min at cooling mode operation.
•
In the Jet Cool mode operation, the room temperature is controlled to the setting temperature, 18
°
C
•
When the sleep timer mode is input while in the Jet Cool mode operation, the Jet Cool mode has the priority.
•
During the JET COOL function at any moment, the A/C starts to blow the cool air with side louvers closed at
extremely high speed for 30 minutes setting the room temp. automatically to 18
°
C.
■
Jet Cool Mode Operation (H/P Model)
•
While in heating mode or Fuzzy operation, the Jet Cool key cannot be input. When it is input while in the other
mode operation (cooling, dehumidification, ventilation), the Jet Cool mode is operated.
”
•
In the Jet Cool mode, the indoor fan is operated at super-high speed for 30 min at cooling mode operation.
•
In the Jet Cool mode operation, the room temperature is controlled to the setting temperature, 18
°
C
•
When the sleep timer mode is input while in the Jet Cool mode operation, the Jet Cool mode has the priority.
•
During the JET HEAT function at any moment, the A/C starts to blow the hot air with side louvers closed at
extremely high speed for 60 minutes setting the room temp. automatically to 30
°
C.
CLOSED
OPEN
< Cooling Mode >
7
°
CLOSED
OPEN
< Heating Mode >
7
°